2010 Log Splitters

38

6.

Remove the six screws that secure the log dislodger
to the beam using a 9/16” wrench. See Figure 5.3.

7.

Remove the nut and bolt that attach the wedge to
the cylinder ram using a pair of 3/4” wrenches.

8.

Remove the cylinder from the log splitter.

9.

Install the cylinder by following the previous steps in
reverse order.

NOTE: When tightening hoses with O-ring face fit-

tings, hold the hose so that the center part of
it does not rotate against the O-ring while the
swivel section is tightened. If the center part
rotates, the O-ring can be damaged and it
will leak under pressure.

10.

Fill the hydraulic reservoir.

11.

Start the log splitter.

12.

Cycle the ram 12 times to purge air from the hydrau-
lic system.

13.

Check hydraulic fluid level, fill as needed.

14.

Test run the splitter in a safe area before returning it to service.

Figure 5.3

Log dislodger

Figure 5.4

Wedge bolt