beautypg.com

Checkline DT-5TS User Manual

Page 17

background image

17

DT-5TXR-FVTR/DT-5TXR-FVC (continued)
Instructions to set the analog output characteristics are
as follows:

1.

Press the FUN button eleven times; the display will reflect:

Displayed is the minimum RPM (factory setting).

4.

Using the numeric buttons, enter the minimum
number of RPM to be monitored.
For example: if using the 0 to 10VDC output and the
minimum RPM to be monitored is 1,000, then 1 0 0 0
would have to be entered; this will provide a 0VDC
output at 1,000 RPM.

5.

Press the FUN button again; the display indicates:

The display reflects the factory setting.

6.

Use any of the lower buttons to toggle between
the two settings for the update time for the analog
output. “0” means that the update time will be
approximately 10 msec, “1” indicates that the update
time will correspond with the display update time
already chosen (see “Setting Mode Parameters” #4).

7.

Press the FUN button; display will reflect:

The display shows that the maximum RPM is set for
1,000 (factory setting).

2.

Using the NUMERIC buttons, enter the maximum
number of RPM to be monitored.

For example: if using the 0 to 10VDC output and the
maximum RPM to be monitored is 1,500, then 1 5 0 0
would have to entered; this will provide a 10VDC
output at 1,500 RPM.

3.

Press the FUN button; the display will show:

The display shows the factory setting.

8.

Use the lower buttons to program the desired offset
percentage setting for the analog output. This
number can be from –100% to 100%.

9.

Press the SET button to store the analog output
characteristics and exit.