3. Open the 3-roller system by pushing the

Thumbpiece forward until the outer rollers
extend beyond the Filament Guide.
Position the DTMB so that the process
material contacts the Filament Guide and
passes between the outer rollers and the
middle sensing roller.

4. Release the Thumbpiece SLOWLY until

it returns to its original position. Do
not let it snap back as this could
effect the calibration and damage
the instrument.
The display will begin
to show tension readings.

5. Press the key to start and stop

the Measuring Interval.

The M indicator will blink on and off
indicating that the memory is active.
Refer to Built-In Memory, Section 6.00.

STORE

Filament

Filament guide

Thumbpiece

19

8.00 GENERAL NOTES

8.10 Turning Power On/Off

Turn Power On: Press key

Turn Power Off: Press and the key

for five (5) seconds

Note: DTMB will power off automatically
after 90 seconds of inactivity, except for the
following instances:

• Memory Mode configured for Standard - NAPO (No Auto Power Off)
• When AC Adapter is used

8.20 LCD Display Indications and Codes

.

.

8.21 Over Range Display

When a displayed value is flashing on & off,
this indicates that this reading is higher than
the maximum range of the unit. The accuracy
of the flashing value is not guaranteed. When
all F’s are displayed, this indicates that the
current value greatly exceeds the maximum
range of the unit.

8.22 EProm Error

When this code is displayed, the EProm is
not responding properly. Try turning the
power off and then on again. Try this a few
times. If code will not clear, contact factory.

POWER

EXIT

POWER

EXIT

Flashing
display
values

All “F’s” in
display

“E0009” in display