beautypg.com

Get new sample alignment lock value – Aviom 6416i User Manual

Page 59

background image

32

A

dvANced

F

uNctioNs

The red LED indicates that the system default sample alignment lock values

are being used.

To get sample alignment info, press the

F

unCtion

button, followed by the

C

hannEl

11 a

CtivE

button. Press

E

ntEr

; the LEDs in the Channel 11 meter strip

are used to indicate the current value in use.

The red (Clip) LED indicates that the system’s default values

are being used. (This is set with Function 14.)
The green (Signal) LED indicates that stored values are

being used. (This is set with Function 13.)

Get New Sample Alignment Lock Value

To generate a new sample alignment lock value, use Function 12. This

Function can only be performed at the Control Master when the network is

unlocked.

Press the

F

unCtion

button, followed by

C

hannEl

12 a

CtivE

button. The sixteen

yellow channel meter LEDs and the Enter/Cancel LED will flash, indicating that

this operation will replace the currently stored value. Press

E

ntEr

to generate

a new sample alignment value, or press

C

anCEl

to exit without updating the

stored value.

Values are stored in each module’s memory but are not put into use until

Function 13 (Use Stored Sample Alignment Values) is performed, which

activates the stored sample alignment values. The module must be the

network Control Master to use its stored value. Use Function 11 to get info on

the current values in use.

When the stored sample alignment lock value is being used, a new sample

alignment lock value should be calculated each time the network sample rate

is changed, or when the system configuration changes. (Changes include the