Sample rate, Changing the sample rate – Aviom 6416i User Manual
Page 46
19
F
roNt
P
ANel
F
eAtures
is only when a digital module is part of the network that the Control Master
and Clock Master can be separate devices.
Sample Rate
Pro64 networks can operate at sample rates in three ranges without the use
of sample rate converters. The current network sample rate also determines
the number of available A‑Net Slots.
Sample Rate
A-Net Slots Available
44.1/48kHz
64
88.2/96kHz
32
176.4/192kHz
16
In an all‑analog network, the sample rate can be set at the Control Master to
the following:
44.1kHz
•
48
• kHz
88.2
•
kHz
96
• kHz
176.4
•
kHz
192
•
kHz
When an external clock is used with a Pro64 digital I/O device, the system
can lock to any sample rate within the range sample rate that is displayed in
the table below.
Pro64 Series Supported Sample Rates
Sample Rate
Minimum
Maximum
1x 44.1/48kHz
39.7kHz
52kHz
2x 88.2/96kHz
79.4kHz
104kHz
4x 176.4/192kHz
158.8kHz
208kHz
Changing the Sample Rate
The network sample rate can be changed only at the Clock Master. Changing
the sample rate is done with the selection button found below the Sample
Rate LED readout.
To choose a new sample rate, press the selection button beneath the sample
rate list. Pressing the button selects the next sample rate in the list and
immediately starts blinking the new rate’s LED and the Enter/Cancel LED;