Sample rates and a‑net slots, Channel activation button, Sample rates and a-net slots – Aviom 6416i User Manual
Page 47

20
F
roNt
P
ANel
F
eAtures
confirmation is required. To confirm the new sample rate, press the
E
ntEr
button. To exit without changing the sample rate, press
C
anCEl
.
Pressing the selection
button will cycle through the
available sample rates.
Attempting to change the sample rate on a module that is not the Clock
Master will cause the Sample Rate and Clock Master LEDs to flash to indicate
the error.
Sample Rates and A-Net Slots
Changing the network sample rate has a direct effect on the availability of
A‑Net Slots. For example, setting the sample rate to 96kHz makes only 32
Slots available, numbers 1 through 32. Slot numbers 33‑64 are no longer
available.
If at the 48kHz sample rate an input module such as the 6416i is set to the
Slot range starting at 33 or 49 and has active channels, these channels will be
deactivated when the sample rate changes to 96kHz. These Slot assignments
no longer exist in the network.
Channel Activation Button
Each of the sixteen line‑level input channels on the 6416i can be made active
on the network individually using the lighted Active button found below
the gain range switch on each channel. Activating a channel assigns it to an
A‑Net Slot, making it part of the network and available to any output module
in the network.