Setting the a‑net slot range, A‑net transmit, A-net transmit – Aviom 6416i User Manual
Page 44: Setting the a-net slot range

17
F
roNt
P
ANel
F
eAtures
Starting Slot Displayed
A-Net Slot Range
01
Slots 1‑16
17
Slots 17‑32
33
Slots 33‑48
49
Slots 49‑64
Keep in mind that the number of available Slots is determined by the current
network sample rate as set by the Clock Master.
Setting the A-Net Slot Range
To set a Slot range, use the inc/dec selection buttons found below the A‑Net
Slot display to select the desired range. When the selection button is pressed,
the new range displayed will start to blink, as will the Enter/Cancel button’s
LED. This indicates that confirmation is required to complete the change.
Press
E
ntEr
to set a new range or press
C
anCEl
to exit without changing
the A‑Net Slot range and return to the previous setting. If no press of the
Enter/Cancel button is detected within a brief period of time, the interface
will automatically cancel the range change request, returning to the previous
state.
Setting a new Slot range on the 6416i will deactivate any currently active
channels.
A-Net Transmit
The A‑Net Transmit section displays information about the current network
mode, which can be set to Auto or Manual only at the network’s Control
Master. When the Pro64 network is operating in Auto Mode, the red Auto LED
will be lit, and no user settings are available on a per‑module basis. It does
not matter which rear‑panel A‑Net port (A or B) is used when connecting
devices to the network.
Selection button
The Control Master can set the network mode to Auto or Manual.
In Manual Mode, the user has the option of directing A‑Net data to either or