beautypg.com

Configuring a t1/e1 port for a wan connection – Cisco IAD2430 User Manual

Page 79

background image

4-7

Cisco IAD2430 Series Integrated Access Devices Hardware Installation Guide

OL-4234-06

Chapter 4 Powering On Cisco IAD2430 Series IADs

Initial Configuration Procedures

Configuring a T1/E1 Port for a WAN Connection

The T1/E1 port supports balanced T1/E1 according to ANSI T1.403 and has a built-in CSU/DSU.

To configure basic T1/E1 controller settings to support Point-to-Poing Protocol (PPP), High-Level Data
Link Control (HDLC), or Frame Relay (FR), follow these steps, beginning in global configuration mode:

Command

Purpose

Step 1

Router# configure terminal

Enters global configuration mode.

Step 2

Router(config)#

enable password

password

Sets a password for the privileged EXEC mode.

Step 3

Router(config)# interface FastEthernet 0/0

Enters interface configuration mode.

Step 4

Router(config-if)# ip address

IP-address subnet-mask

Enters the IP address and subnet mask for the Fast
Ethernet (10/100BASE-T) port.

Step 5

Router(config-if)#

no shutdown

Activates the 10/100BASE-T port.

Step 6

Router(config-if)#

exit

Returns to global configuration mode.

Step 7

Router(config)#

line vty 0 4

Enters line configuration mode.

Step 8

Router(config-line)#

password

password

Sets a password for remote access to the Cisco IAD.

Step 9

Router(config-line)#

end

Returns to privileged EXEC mode.

Step 10

Router# copy system:running-config nvram:

startup-config

Saves the configuration.

Command

Purpose

Step 1

Router(config)# controller T1/E1 1/0

Enters controller configuration mode by controller
number. Slot and port numbers vary.

Step 2

Router(config-ctrl)# clock source {internal | line |

loop-timed

}

Configures the controller clock source for a DS1
link.

If the clock source is a network device attached to
the T1/E1 port that you are configuring now, select
the line option. For any other clock source (internal
or a network device attached to any other port),
select the internal option.

Step 3

Router(config-ctrl)# description

line

Enters a description of the controller, such as the
destination or its application. The description can be
as many as 80 characters long.

Step 4

Router(config-ctrl)# cablelength short {133 | 266 |

399

| 533 | 655}

or

Router(config-ctrl)# cablelength long {gain26 |

gain36

} {-15db | -22.5db | -7.5db | 0db}

Configures the cable length if the length is
655 ft (200 m) or shorter.

or

Configures the receive gain and transmit attenuation
if the cable length is longer than 655 ft (200 m).

Step 5

Router(config-ctrl)# framing {sf | esf}

If necessary, changes the DS1 link framing format.
The default is SuperFrame (sf).

Step 6

Router(config-ctrl)# linecode {ami | b8zs}

If necessary, changes the line encoding format for
the DS1 link. The default is ami.