Operation safety, Condensate condenso, Condensat – STIEBEL ELTRON Accelera 300 E User Manual
Page 8: Hot water outlet, Salida de agua caliente sortie eau chaude, Cold water inlet, Entrada para agua fría entrée eau froide, 4 etl designation, 5 appliance labels, Attention

OPERATION
Safety
8
| Accelera® 220-300 E www.stiebel-eltron-usa.com
!
CAUTION
Hydrogen gas is produced by this heater in a hot water
system that has not been used for a long period of time
(2 weeks or more). Hydrogen gas is extremely fl amma-
ble. To reduce the risk of injury under these conditions,
it is recommended that the hot water faucet be opened
for several minutes at the kitchen sink before using any
electrical appliance connected to the hot water system.
When hydrogen is present, there will probably be an
unusual sound such as air escaping through the pipe as
the water begins to fl ow. There should be no smoking or
open fl ame near the faucet at the time it is open.
!
Material losses
If you disconnect the appliance from the power supply, it
is no longer protected against frost.
Do not interrupt the power supply to the appliance.
!
Material losses
Never cover this appliance. Covering the air intake or air
discharge leads to a reduced air supply. If the air supply
is restricted, the operational reliability of the appliance
cannot be guaranteed.
!
Material losses
Only operate the appliance when the DHW tank has been
fi lled.
!
Material losses
Keep the appliance installation room free from air con-
taminated with oil or salt and corrosive or explosive sub-
stances.
2.4
ETL
designation
The ETL designation shows that the appliance meets all essential
UL and CAN/CSA requirements. This appliance conforms to:
- UL Standard 1995
- UL Standard 174
- CAN/CSA Standard C22.2 No.236-05
- CAN/CSA Standard C22.2 No.110-94
2.5 Appliance
labels
1. Type plate label for the Accelera 220 E
Accelera 220 E
Stiebel Eltron Inc.
17 West Street
West Hatfield, MA 01088, USA
800.582.8423
[email protected]
Conforms to UL STD. 1995
Conforms to UL STD. 174
Certified to CAN/CSA STD. C22.2 No.236-05
Certified to CAN/CSA STD. C22.2 No.110-94
Part number/code article:
233058
Electrical/électrique
Voltage/tension:
Single phase 220-240 V
Frequency/fréquence:
50 / 60 Hz
Breaker/disjoncteur:
15 A
P
nmax
(rated power input)/puissance nominale:
2200 W
Maximum allowable ratings/courant nominal:
2200 W, 9.17 A
Protection class/indicie de protection:
IP 24
Heat pump/pompe à chaleur:
P
N
(Air 107.6°F / Water 149°F):
0.54 kW
Refrigerant/frigorigène:
R-134a
Refrigerant charge/frigorigène poids de remplissage:
1.874 lb / 850g
Max. operating pressure/max. pression de service:
348.1 PSI / 2,400 kPa
Lock rotor current/puissance blockade:
15.3 A
MCA:
14 A
Rated compressor load/courant nominale du compresseur:
2.5 A
Motor fan/moteur de ventilateur:
24 W
DHW cylinder/DHW cylindre:
Backup heating element/chauffage d'appoint:
1690 W
Max. operating pressure/max. pression de service:
87 PSI / 600 kPa
Max. operating temperature/max. temperature de service:
168.8°F / 76°C
Tank material/matériau réservoir:
Steel
Nominal capacity/capacité nominale:
58.12 gal / 220 l
Tank test pressure/contrôle de réservoir:
130.5 pSI / 900 kPa
No.:#### / ######
Made in EU/Fabriqué en UE
Read the instructions carefully.
Tested for leaks.
Lira attentivement la notice.
Étanchéité testé.
285872-34892
XX
XX
XX
-
XX
XX
-
XX
XX
XX
2. Condensate drain information label
315683-38055
Condensate
Condenso
31
1801-38055
Condensat
3. Hot water outlet location label
Hot Water Outlet
311803-38055
Salida de agua caliente
Sortie eau chaude
4. Cold water outlet location label
Cold Water Inlet
311802-38055
Entrada para agua fría
Entrée eau froide
5. Power connection information label
Power supply
Disconect power supply
Before opening the cover
!Attention!
Must connect to
240 V, 15 A
Double-pole
Circuit breaker