Preventative maintenance, Preventive maintenance – Cleveland Range IA-MKDL-60-CC User Manual
Page 31

_______________________________________________________________________
_
PREVENTIVE
MAINTENANCE
COOK/CHILL MIXER & PASTA KETTLES
A.
AUTOMATIC DUMP VALVE
Weekly
-
Check air collector regulator for moister, dirt, and proper pressure
-
Check all orings and seals and gaskets
-
Check valve operation
-
Lubricate with light oil when needed
-
Check air hose for leaks or signs of wear
B.
TILT MECHANISM ( Hydraulic Tilt )
Weekly
-
Check for leaks
-
Check for smooth operation
-
Check switches
Yearly
-
Change hydraulic fluid every two years. (1 1/2 gallons of
FOOD GRADE hydraulic fluid) ( Shell Telis #5 )
( Electric Tilt )
Weekly
-
Check for smooth operation
-
Check switches
Monthly
-
Check for movement in mechanism
-
Grease trunnions monthly ( Food Grade Grease )
C.
AIR PRESSURE
Weekly
-
45 psi dump valve - 15 psi for jacket purge
-
Air must be clean and dry
-
Check all air lines & fittings for leaks
D.
STEAM TRAP
Monthly
-
Check proper operation