beautypg.com

Carrier 58TMA User Manual

Page 3

background image

1. Horizontal and Downflow.

Each furnace requires 2 filters which are installed in the
return-air duct. (See Fig. 4 and 5.) To remove filters for
cleaning or replacement, proceed as follows:

a. Turn off electrical supply before removing blower access

door.

b. Remove blower access door.

c. Reach up behind top plate, tilt filters toward center of

return-air plenum, remove filters, and clean as needed.
Replace if torn.

d. Furnaces are equipped with permanent, washable filters.

e. Clean filters by spraying tap water through filter from

opposite direction of airflow.

f. Rinse and let dry. Oiling or coating of filters is not

recommended or required.

g. Reinstall filters.

h. Replace blower access door and turn on electrical supply to

furnace.

2. Upflow.

Each furnace requires 1 or 2 filters which are installed in the
blower compartment. (See Fig. 6.) To remove filters for
cleaning or replacement, proceed as follows:
a. Turn off electrical supply before removing blower and

control access doors.

b. Release filter retainer from clip at front of furnace casing.

(See Fig. 6.) For side return, clips may be used on either or
both sides of the furnace.

c. Slide filter out.

d. Clean filters by spraying tap water through filter from

opposite direction of airflow.

e. Rinse and let dry. Oiling or coating of filter is not

recommended or required.

f. Place filter in furnace.

g. Replace blower and control access doors and turn on

electrical supply to furnace.

BLOWER MOTOR AND WHEEL — For long life, economy, and
high efficiency, clean accumulated dirt and grease from the blower
wheel and motor annually.

The following steps should be performed by a qualified service
technician:

Some motors have prelubricated sealed bearings and require no
lubrication. These motors can be identified by the absence of oil
ports on each end of the motor. For those motors with oil ports,
lubricate as follows:

Fig. 4—Horizontal Filter Arrangement

A82173

FIELD-SUPPLIED
FILTER RETAINERS

AIRFLOW

D

12

4

Fig. 5—Downflow Filter Arrangement

A88486

RETURN-AIR

PLENUM

AIRFLOW

ACCESS DOOR

INSTALLATION

POSITION

OF FILTERS

Fig. 6—Model 58TUA Upflow

A93393

DRAFT
SAFEGUARD
SWITCH

PRESSURE
SWITCHES

FILTER
RETAINER

WASHABLE
FILTER

MOUNTING

SCREWS

MAIN

LIMIT

SWITCH

RELIEF

BOX

MANUAL

RESET

LIMIT

SWITCH

CONTROL

3