Appendix, Example, A1 example – Eclipse Combustion EGA4 User Manual
Page 48: Ecoline 4000, 9% co, 0% co 1
Instruction Manual MM850481 ed.01
APPENDIX
A1 Example
The following steps show how you can make a quick measurement using the EGA4 portable analyzer.
1. Switch
EGA4 on. It will begin the autozero and the autodiagnostic procedure. System error and trouble will be
displayed if encountered.
EcoLine 4000
Serial Num: 1257
Version : 1.001
! Don t insert !
! probe in chimney !
Op.: Antonio
Bat: 5.2V (23.5°C)
Autozero: 180 sec
MENU
MEASURE
–
2. Select the combustible used by burner. It is possible choosing between 4 preset and other 6 customizable types.
! Now insert !
! probe in chimney !
--- FUEL --
Natural Gas
TAG SELECTION
ANALYS.
–
3. Connect the sampling probe electrical and pneumatic terminals to the EGA4.
4. Insert the sampling probe in chimney. Be sure for mechanical positioning and flue gas intercepting.
5. Press
ANALYSIS] (F1) key to start the measurements. Select the desired data page using [▲] and [▼] keys. Zoom
in or out to enlarge or reduce the visualized characters using the [X] and [W] keys.
O
2
20.9%
CO
2
0.0%
CO 1
ppm
Ref O2
–
O2 20.9%
:
CO 2000p
Ta 20.2C
:
Eff 0.99
Tf 400.3C
:
NO2 100p
η 95.7%
:
CO2 10.2p
:
NOx 500p
:
Ref O2
–
6. Finishing
measurement procedure, press the [PRINT] key to print one or more reports.
MEASURE HOLD
PRESS [PRINT]
NO. COPY 1
MODEL Standard
ESCAPE
–
FEED
7. Dismount the system and switch it off. All system can be put back in a rugged and practical case.
48