beautypg.com

Coolift – Magliner COOLIFT User Manual

Page 14

background image

1-800-MAGLINE (624-5463)

Page 14 www.magliner.com

CooLift

®

Using the AC Charging Unit

1) Connect the AC charger plug to an AC outlet (120v domestic or 230v international).

2) Plug the output cord from the charging unit into the charging port located on the top of the

battery box.

3) Turn the power switch on the charging unit to the “On” position.

4) When disconnecting the charging unit from the CooLift or a supplementary battery box:

a) Turn the charging unit power switch to “Off” position;

b) Unplug the charging unit from the power source (AC outlet);

c) Disconnect the charging unit from the charging port.

A completely drained battery needs 2 hours to fully charge. The LED will illuminate to

indicate one of the following conditions:

Solid Yellow – Battery is charging

Solid Green – Battery has fully charged and is ready for use

Flashing Green – The output is not connected; check all

connectors and fuses

NOTE: Your AC charger model may have two LED lights. If your charger has two LEDs, a solid red

light on the charging unit is an indication the power is on and should remain on the entire time it is

plugged into the power source and the battery.

NOTE: There are two operational fuses on the charging unit located at each end. A spare fuse is

located adjacent to the main power connection.

Note: Battery may be charged as often as desired. Magline recommends charging at least

once after each delivery route is complete.