FI-90 Specifications

Display:

7-segment LCD, 6-1/2 digits plus sign, .5 inch high, movable decimal, with
7 annunciators

Display Update Rate:

Two times per second

Analog-to-Digital

Conversion Rate:

60 times per second

Resolution:

Up to 10,000 divisions standard

Controls:

Pushbutton zero; pushbutton peak-hold; pound-, kilogram-, Newton-scroll selection;
PRINT, MENU, and SELECT keys for configuration; ON / OFF switch (optional: used
only on alkaline battery option); BATT / AC switch (optional: used on rechargeable
battery / AC versions)

Peak Detection Rate:

60 times per second

Peak Detection:

Threshold 1% of capacity setting

Accuracy :

Span: ±5.0 ppm/C

Zero: ±.066 uV/C (-10 to 40°C)

Linearity:

±0.005% of capacity, maximum

Repeatability:

±0.005% of capacity, maximum

Hysteresis:

0.005% of capacity, maximum

Power:

Std - 117VAC +10/-15% 50/60Hz

5 watt

Opt - 230VAC +10/-15% 50/60Hz

5 watt

Opt - 12VDC +10/-15%

130mA max.

Load Cell Drive Capacity:

Up to four 350-ohm load cells. Up to twelve 1000-ohm load cells.
(+5VDC load cell excitation voltage)

Environment:

-10 to 40°C (14 to 104°F)
10 to 90% relative humidity

Calibration

and Programming:

All calibration and programming is done through the front panel with data stored in
non-volatile memory.

Analog Range:

-0.14 to +3.5 mV/V

Scale Capacities:

.00001 to 999999, programmable to any number between these limits

Scale Division Sizes:

.0001 to 20000, programmable to any division size between these limits

Pushbutton-Zero Range:

0 to ±100% of capacity; programmable in any percentage of indicator capacity;
independent positive and negative limits; unit will not allow zeroing beyond capacity.

Overrange Capacity:

The indicator displays force measurements up to and including full-scale capacity