Dillon FI-90 User Manual
Page 16

16
2. Enter a new setpoint value in
register #0, using the procedure
presented in the section, Entering
Data with Arrow Keys. Before you
enter any numeric values, specify
a negative setpoint, if appropriate
for your application. To display a
negative sign, "-", use
UP ARROW to scroll through all
digits and characters until the
sign is displayed. Then press
LEFT ARROW to place a new
edit character in the edit position.
To display a decimal point in your
setpoint, scroll similarly through
all digits until the decimal is
displayed. Use the arrow keys to
enter all digits of the new
setpoint. When the correct
setpoint is displayed, press
PRINT / SELECT to accept the
value and redisplay. . .
CutOFF.0
then press MENU to move to the
next register (register #1). . .
CutOFF.1 is displayed (if the
second setpoint has been configured;
if not, you now see the time display).
The 1 now displayed stands for
setpoint register #1.
3. Press PRINT / SELECT. . .
nn.n is the current value in register
#1.
4. Enter a new setpoint in cutoff
register #1 (See #2 and Entering
Data with Arrow Keys).
5. Press PRINT / SELECT to
accept the value and redisplay. . . CutOFF.1
then press MENU to see the
clock or GROSS / PEAK to go
back to gross or peak-view mode.