1. Power up the indicator. . .

The FI-90 powers up in the same

mode it was in when power was

removed.

2. Access the gross mode. If the

gross annunciator is not

illuminated, press

GROSS / PEAK once. . .

The gross annunciator illuminates

(See Figure 2).

3. Zero the FI-90 by pressing

ZERO / CLEAR (Any stable

applied force up to full-rated

capacity may be zeroed off). . .

0 is displayed. Any small changes

in force are zero tracked automati-

cally and the displayed zero is

maintained.

4. Select unit of measure by

pressing UNITS. . .

The units annunciator indicates your

selected unit of measure.

5. Apply force . . .

The applied gross force is displayed.

This procedure allows the FI-90 to monitor a varying force and hold the peak

value.
1. With the indicator powered up in

the gross mode, zero by pressing

ZER0 / CLEAR and apply force. . . Gross displayed value increases to

reflect increasing live force.

2. Press GROSS / PEAK to access

peak-view mode. . .

The peak annunciator comes on.

Displayed is the incrementing peak

value. It reflects the live gross force

continuing to increase.

3. Remove force, or await removal of

force. . .

The force now displayed is the

retained peak value. Retained peak

is measured precisely at the maxi-

mum load sensed by the indicator

before force is reduced. Retained

peak value stays displayed while the

live gross force drops.

Measuring Gross Force

Measuring Peak Force

In peak load applications,

removal of force occurs when

maximum tension or compres-

sion strength of the material or