Set up baud rates and modem/slip/ppp parameters – CANOGA PERKINS 2346 T3 Fiber Optic Modem User Manual
Page 19
EdgeAccess Universal Chassis System
2346 T3 Modem
3-7
2. At the Alarm Output Configuration screen, type the number for an alarm and press
Table 5.
3. Press
4. To return to the Main Menu, press
These selections do not affect how the CIM Major and Minor LEDs report alarms.
Table 5. Alarm Output Options
Alarm
When enabled, sends an alarm if. . .
2) LOS/CLS
Loss of Signal (electrical)/Composite Loss of Signal (optical); one or
both received signals fail; default is Off
3) SQL
Squelch occurs (for received signal); default is Off
4) Configuration
The 2346 is set up incorrectly or the local and remote software versions
do not match; default is Off
5) Power/Fan
Power is low or fan is off; default is Minor
6) Power-On Self Test Modem failed when power was turned on; default is Major
7) BERT
Bit Error Rate Test (BERT) detects data errors; for details on BERT
results, see page 3-12; default is Off
Note: The Bit Error Rate Test (BERT) sends a continuous 127-bit sequence within the optical data
stream to check for bit errors while the optical signal remains in sync.
Set Up Baud Rates and Modem/SLIP/PPP Parameters
Although the default values for the communication parameters meet requirements for most systems,
you may need to change them for your particular situation.
To reset the VT100 baud rate, follow these steps:
1. At the Main Menu, type
4
, "Utilities," and press
2. At the Utilities menu, type
3
, "VT100 Baud Rate," and press
cycle between 9600 and 19200 bps.
3. To return to the Main Menu, press
To access the Modem/SLIP/PPP Configuration menu, follow these steps:
1. At the Main menu, type
4
, "Utilities," and press
2. At the Utilities menu, type
4
, "Modem/SLIP/PPP Configuration," and press
3. To select the baud rate for the serial port, type
4
, "Modem/SLIP/PPP Configuration," and press
38400, 57600, or 115200 bps.