Manage and check traps and alarms – CANOGA PERKINS 2346 T3 Fiber Optic Modem User Manual
Page 18
EdgeAccess
®
Universal Chassis System
2346 T3 Modem
3-6
• BOOTP Enabled: Enable this if the module needs to obtain its IP address from a BOOTP
server; when the unit has an IP address, disable BOOTP
• Serial Port Config: Set the type of serial port connection: VT100, SLIP, or PPP
• Telnet Timeout: Set the time with no activity until a Telnet connection automatically logs out
3. To return to the System Configuration menu, press
Manage and Check Traps and Alarms
Traps are messages that require management attention and are routed to the Network Manager, but do
not trigger alarms. Conditions that generate an alarm require immediate attention. Enable or disable
traps on the Trap Configuration screen and enable or disable alarms on the Alarm Output
Configuration screen.
Use the Trap Configuration screen to view the current configuration and to enable or disable traps for
the 2346. For a list of events that trigger traps, see Table 4. To set up the traps, follow these steps:
1. At the System Configuration menu, type 3, "Trap Configuration," and press
2. At the Trap Configuration screen, type the number for a trap and press
3. Press
4. To return to the Main Menu, press
These selections do not affect how the Major and Minor LEDs on the CIM report alarms.
Table 4. Trap Configuration Options
Type of Trap
When enabled, sends a Trap if. . .
2) LOS/CLS
Loss of Signal (electrical)/Composite Loss of Signal (optical); one or
both received signals fail
3) SQL
Squelch occurs (for received signal)
4) Configuration
The 2346 is set up incorrectly, including mismatches with other modems
5) Diagnostic
Loopback is enabled or disabled
6) Authentication
An unauthorized host attempts SNMP access to the 2346
7) Power/Fan Malfunction
Power is low or fan is off
8) Cold Start
The 2346 is reset by a power failure or forced reset
9) Alarm Input
UCS 1001 function; see the UCS 1001 User Manual
10) Security Violation
Not used
Use the Alarm Output Configuration screen to view the current configuration and to enable or disable
alarms for the 2346. For a list of events that trigger alarms, see Table 4. To set up the alarms, follow
these steps:
1. At the System Configuration menu, type 4, "Alarm Output Configuration," and press