beautypg.com

Manage and check traps and alarms – CANOGA PERKINS 2346 T3 Fiber Optic Modem User Manual

Page 18

background image

EdgeAccess

®

Universal Chassis System

2346 T3 Modem

3-6

• BOOTP Enabled: Enable this if the module needs to obtain its IP address from a BOOTP

server; when the unit has an IP address, disable BOOTP

• Serial Port Config: Set the type of serial port connection: VT100, SLIP, or PPP
• Telnet Timeout: Set the time with no activity until a Telnet connection automatically logs out

3. To return to the System Configuration menu, press .

Manage and Check Traps and Alarms

Traps are messages that require management attention and are routed to the Network Manager, but do
not trigger alarms. Conditions that generate an alarm require immediate attention. Enable or disable
traps on the Trap Configuration screen and enable or disable alarms on the Alarm Output
Configuration screen.

Use the Trap Configuration screen to view the current configuration and to enable or disable traps for
the 2346. For a list of events that trigger traps, see Table 4. To set up the traps, follow these steps:

1. At the System Configuration menu, type 3, "Trap Configuration," and press .

2. At the Trap Configuration screen, type the number for a trap and press . See Table 4.

3. Press to cycle to Enabled or Disabled and press .

4. To return to the Main Menu, press .

These selections do not affect how the Major and Minor LEDs on the CIM report alarms.

Table 4. Trap Configuration Options

Type of Trap

When enabled, sends a Trap if. . .

2) LOS/CLS

Loss of Signal (electrical)/Composite Loss of Signal (optical); one or
both received signals fail

3) SQL

Squelch occurs (for received signal)

4) Configuration

The 2346 is set up incorrectly, including mismatches with other modems

5) Diagnostic

Loopback is enabled or disabled

6) Authentication

An unauthorized host attempts SNMP access to the 2346

7) Power/Fan Malfunction

Power is low or fan is off

8) Cold Start

The 2346 is reset by a power failure or forced reset

9) Alarm Input

UCS 1001 function; see the UCS 1001 User Manual

10) Security Violation

Not used

Use the Alarm Output Configuration screen to view the current configuration and to enable or disable
alarms for the 2346. For a list of events that trigger alarms, see Table 4. To set up the alarms, follow
these steps:

1. At the System Configuration menu, type 4, "Alarm Output Configuration," and press .