SYSTEM LOG
Description
Type
Username
Local
Date/Time
Local User Port Link Up
Trap
SYSTEM
*
02-Oct-2003 13:17:36.68
Side Band Management Online
Trap
SYSTEM
*
02-Oct-2003 15:28:15.80
Log initialized
Trap
SYSTEM
*
02-Oct-2003 16:30:14.00
user attempted to login with invalid password
Security
SYSTEM
*
02-Oct-2003 16:37:11.60
Cold Start
System
SYSTEM
*
02-Oct-2003 16:37:14.80
user logged in
Trap
admin
*
02-Oct-2003 16:59:26.60
Select [(F)irst, (N)ext, {P)rev, (L)ast, (C)lear]
Figure 33. System Log Screen
4.11 Utilities
Use the Utilities screen to set the time and date, reset a configuration, or enable or disable the remote
console port. See Figure 34 and Table 10. To access the Utilities screen, follow this step:
1. From the Main Menu, type
6
, "Utilities," and press
2. To return to the Main Menu, press
UTILITIES
1) Set Date and Time
2) Reset Configuration To Default
3) Reset Remote Configuration To Default
4) Remote Craft Port:
Enabled
5) Modem/Slip/PPP Baud Rate
19200
6) Modem Initialization String
AT
7) PING generation
8) Static ARP Table
9) Dynamic ARP Table
Figure 34. Utilities Menu Screen
Table 10. Utilities Menu Options
Item
Definition
1) Set Date and Time
Change the time and date information for the modem if
needed; if in a chassis with a DMM, the DMM date and
time overrides the L357
2) Reset Configuration To Default
3) Reset Remote Configuration To
Default
Restores all configurable settings to the defaults except for:
date and time; password; BOOTP; Telnet timeout
4) Remote Craft Port
Enable or disable the console port on the remote module