4.5.3 Trap Configuration
Traps are messages to alert network management about conditions. The DMM logs the traps and the
DMM or Model 1020 transmits them by SNMP to the network manager. At the Trap Configuration
screen, enable or disable traps individually or use the "Master Trap Control" to enable or disable all
traps. See Figure 20. To configure traps, follow these steps:
1. From the Main Menu, type
1
, "System Configuration," and press
Configuration menu appears.
2. From the System Configuration menu type 3, "Trap Configuration," and press
3. At the Trap Configuration menu, type the number for a trap and press
Note: "Master Trap Control" enables or disables all traps. The factory default is Disabled.
4. Press
5. To return to the System Configuration menu, press
TRAP CONFIGURATION
1) Master Trap Control
Disabled
2) Extension Port Link Traps
Enabled
3) Remote Fault Received Traps
Enabled
4) Link Loss Forwarding Traps
Enabled
5) Link Loss Echo Traps
Enabled
6) Remote User Port Link Traps
Enabled
7) Local User Port Link Traps
Enabled
8) Configuration Traps
Enabled
9) Power/Fan/Temperature Traps
Enabled
10) Cold Start Traps
Enabled
11) Side Band Mgmt Channel Traps
Enabled
12) Alarm Input Traps
Enabled
13) Diagnostics Traps
Enabled
14) Authentication Traps
Enabled
Figure 20. Trap Configuration Screen
4.5.4 Alarm Output Configuration
Use the Alarm Output Configuration screen to set any or all alarms to Major, Minor, or Off. See
Figure 21 and Table 6. To configure alarms, follow these steps:
1. From the Main Menu type
3
, "Alarm Output Configuration," and press
Output Configuration screen appears.
2. Type the number for the alarm you want to set and press
3. Press