beautypg.com

Rane MA 3 2003 version User Manual

Page 8

background image

TF 407 & TF 410

MA 3 TRANSFORMER KITS

All features & specifications subject to change without notice DOC 103209

©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 TEL 425-355-6000 FAX 425-347-7757 WEB www.rane.com

9. Once the transformers are securely mounted, lay the unit down (never leave the unit

standing on its end unattended).

10. See Figure 3. The + (hot) jumper must be cut when a transformer is installed. The

– (gnd) jumper may be cut for a fully isolated secondary or left in for a ground

referenced secondary. There are two wire jumpers for each Channel:

Ch 1

+ (hot) W6

– (gnd) W9

Ch 2

+ (hot) W8

– (gnd) W10

Ch 3

+ (hot) W13

– (gnd) W14

11. Cut the required jumper(s).

12. Locate the BLK/WHT primary pair. Twist the wires together.

13. Connect the BLK primary wire:

Ch 1: J8

Ch 2: J15

Ch 3: J25

14. Connect the WHT primary wire:

Ch 1: J20

Ch 2: J11

Ch 3: J22

15. Locate the BLK/RED secondary pair. Twist the wires together.

16. Connect the BLK secondary wire:

Ch 1: J10

Ch 2: J14

Ch 3: J21

17. Connect the RED secondary wire:

Ch 1: J9

Ch 2: J16

Ch 3: J17

18. Use the supplied tie raps to “dress” wires along the rear of the chassis and away

from power transformer and circuit board.

19. Place the supplied Label on the outside of MA 3 to indicate the location and type

of transformer installed.

20. Re-install the top cover.

Gently lay capacitors back toward the rear

Ch 1 Ch 2 Ch 3

Figure 3. Jumpers