beautypg.com

Rane ECS RaneWare User Manual

Page 10

background image

RW Manual-10

System tab

Prog Sig Thresh

Program Signal Threshold adjusts the point at which

audio is detected at the Port 1 Output, thus causing the
Program Signal Status indicator to light.

See also:

Program Sig Offset and P3 Prog Contribute.

Typical default value:

-20 dB

P3 Prog Contribute

Systems requiring the use of ceiling speakers for far-end

reinforcement, beyond that normally provided by the Program
(Port 1) Output, should use Port 3’s Output.

Check this box only when Port 3’s Output drives room

loudspeakers with far-end audio. Never check this box if Port
3’s Output contains near end mic/speech audio since this
causes shabby and unreliable Mic Gating.

When

P3 Prog Contribute is checked, the Port 3 Output

contributes to the Program Signal indicator’s on/off status –
i.e., Progam audio (not near end speech) is heard in the room.

Typical default value: Off (unchecked) unless far-end

audio is fed from Port 3’s Output.

Link Prog Signal

When checked, the

Program Signal Offset and Program

Signal Threshold link to Port 1’s Output level. This allows
the

Program Signal Threshold and Offset to track level

changes as the user adjusts the room audio level (Port 1’s
Program Output).

When

Link Program Signal is checked:

1. If

P3 Prog Contribute is not checked the Program Signal

Offset and Program Signal Threshold track the Program
(Port 1 Output) Level.

System Page

2. If

P3 Prog Contribute is checked the Program Signal

Offset and Program Signal Threshold track the Port 3
Output Level.

Note: This feature is not demonstrable using RaneWare’s

OFFLINE ECS device.

Typical default value: On (checked)

Suppression and level

Check this box when poor room acoustics cause the far-

end to complain about echo. When checked, an adjustable
amount of

Suppression (attenuation) is added at Port 1’s

Input to help reduce echo.

Suppression is active when the

Program Status indicator is lit (i.e., there is Program audio)
and the Mic Status indicator is off (i.e., no one is talking at
any of the Mics).

Typical default value: Off (unchecked)

Noise Gate activation and level

This feature is useful in multipoint conferencing when you

want the near end’s Mic audio (room noise) to be reduced at
the far-end(s). The checkbox enables this feature.

When checked, the

Noise Gate Level attenuates Port 1’s

Input when the Mic Status indicator is off (i.e., no audio
detected at any Mics). This is useful in noisy room situations.

Typical default value: Off (unchecked)

Master Port Delay

This adjustable timer controls the speed at which a Port

becomes the new Master Port.

The Master Port indicates which of the ECB 62e Input

Ports most recently detected audio. This is useful in
multipoint videoconferencing when you need to know which
one of multiple locations is talking.