P-Maintenance (Factory set to OFF)

Press  to select. “P-Maintenance” will appear on the screen when a preset volume is reached. Press < or > to

adjust. Range setting is from Off to 3000 gallons in 100 gallon increments. Press  to set and exit.

Beeper On/Off (Factory set to ON)

Press  to display ON or OFF. Pressing either < or > toggles between on and off.  to set. When ON, this feature

allows you to hear a short beep each time a button is pressed.

Tea Quality Timer (Factory set to OFF)

Press  to Select. Press < or > to adjust from OFF, 0 to 10 hours in 5 second increments. Timing starts when a

brew button is pressed. When time expires, the UCM will emit an audio alarm and the words “Brew Fresh Tea” will

appear flashing on the screen.

Display Brew Time (Factory set to ON)

Press  to display ON or OFF. Pressing either < or > toggles between on and off. When ON brew time displays and

counts down (during the brew cycle). When OFF, only the word Brewing is displayed during the brew cycle.

Display Messages (Factory set to ON)

Press  to display ON or OFF. Pressing either < or > toggles between on and off. This feature allows the operator to

select the message “Rinse Server Before Brewing”. This will be displayed any time the unit is not brewing.

Model Select (Factory set to DUAL SWEET)

Press  to select, < or > to select model. The selections are: TCT-1BATCH, TCT-2BATCH, TCT-3BATCH, TCT-

4BATCH, TCT-SWEET, DUAL DILUTION, DUAL -SWEET, COMBO, COMBO-SWEET. Press  to set. When the

Model Select feature is changed, all settings are reset to the defaults of the newly selected model.
Exit

Press  to select, exits program mode and returns unit to operation.

Beeper On/Off

Exit

Tea Quality Timer

Display Messages

Model Select

P-Maintenance

Displ. Brew Time