Tea Half Batch (Factory set to OFF).

Press  to Select. Press < or > to toggle between OFF and ON. When ON, Half Batch Brew Button is activated.

Tea Drip-Out (Factory set to OFF)

Press  to Select. Press < or > to move to desired time. Settings are OFF, 30 seconds, up to 15 minutes. Increments

are 30 seconds. Press  to Select time.

Sweetener Time (Factory set to 48 Seconds)

Press  to Select. Press < or > to toggle between minutes, seconds or exit. Pressing select  to choose minutes will

increase the minutes. Press  to add minutes. Press < or > to move to seconds or exit.

Temperature (Factory set to Standard Gray & Purple 204ºF)

Press  to Select. Press < or > to choose Standard Gray and Purple 204ºF and then  to set. Tropical Gray and Purple

and 76/308 Gray & Purple 196ºF are the other selections. Temperature range, from 170ºF to 208ºF in 2-degree incre-

ments.

Energy Save Mode (Factory set to OFF)

Press  to Select, < or > ON, OFF or ON 140ºF ,  to set. When in ON, unit will automatically shut off 4 hours from

last brew. When feature is OFF, unit does not have the energy saving mode. In the ON 140ºF position, temperature goes

down to 140ºF, if unit has not brewed in 4 hours. This saves energy by lowering the tank temperature during periods of

non-operation.

Brew Count Odom.

Press  to display total brew cycles. Press ex or Reset Brew Count Total. Press  to Select, Shows total gallons and

total brew cycles on the unit. This feature can be reset.

Brew Count Total

Press  to Select, Shows total gallons and total brew cycles on the unit. This feature is read only and cannot be reset.

Cold Brew Lock (Factory set to 5º F)

Press  to select, < or > to select desired setting (5ºF, 15ºF or OFF), to set.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The

first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for

the Ready to Brew message, however it will brew at any temperature.

Master Reset

Press  to display Are You Sure?, < for Yes, or > for No. When Master Reset is used, the all of the menu selections in

the UCM return to factory defaults.

Service Call (Phone number Factory set to [800] 000-0000)

Press  to display number and change number or < to move place and EX to exit when complete. This number will be

displayed during a Heating system SENSOR ERROR or during a WATER ERROR.

Access Code (Factory set to 1-2-3-4)

Press  to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit.

Banner Name (Factory set to CURTIS)

Press  to display letters and change letters or < to move place and EX to exit. This feature allows up to 14 letters to

be set into the screen display. Entering all blanks (space) disables Banner Name. Banner Name is displayed above the

Ready to Brew message during normal operation.

Temperature

Energy Save Mode

Brew Count Odom

Master Reset

Service Call

Brew Count Total

Cold Brew Lock

Access Code

Sweetener Time

PROGRAM MENUS CONTINUED

Continued on Page 5

Tea Drip-Out

Tea Half Batch

Banner Name