beautypg.com

Wilbur Curtis TCC3S User Manual

Service manual, tea concentrate container short, Ilbur, Urtis

background image

1

NSF International requires the following water connection:

1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine

can be moved for cleaning underneath.

2. This equipment is to be installed with adequate backflow protection to comply with applicable

federal, state and local codes..

3. Water pipe connections and fixtures directly connected to a potable water supply shall be sized,

installed and maintained in accordance with federal, state, and local codes.

Important Safeguards/Symbols

Service Manual, Tea Concentrate Container Short

This appliance is designed for commercial use. Any servicing other than cleaning and maintenance

should be performed by an authorized Wilbur Curtis service center.

• Do NOT immerse the unit in water or any other liquid

• Never clean with scouring powders, bleach or harsh chemicals.

Symbols:

WARNINGS – To help avoid personal injury

Important Notes/Cautions

Sanitation Requirements

Curtis TCCS Units are Factory Pre-Set and Ready to Go… Right out of the Box.

Generally there will never be a reason to change factory settings. However, should you need to

make slight adjustments to meet your tea needs, adjustment instructions are provided later in this

manual.

System Requirements:

• Water Source 30 – 90 PSI (Minimum Flow Rate of 1 GPM). If incoming water supply is greater

than 90 PSI, additional regulation is required to meet the range.

• Water pipe connections and fixtures directly connected to a potable water supply shall be

sized, installed and maintained in accordance with federal, state, and local codes.

SETUP STEPS

The unit should be level (left to right and front to back), located on a solid counter top. Connect a

water line from the water filter to the TCCS server.

NOTE: Some type of water filtration device must be used to maintain a trouble-free op-

eration. (In areas with extremely hard water, we suggest that a sedimentary and taste &

odor filter be installed.) This will prolong the life of your system and enhance tea quality.

INSTALLATION
1. Remove dispenser from carton.
2. Run a water line to the inlet fitting behind the dispenser. Flush the new waterline to remove for-

eign particles.

3. Connect a ¼” flared flexible or copper waterline to the male fitting on the back

of the dispenser.

4. Locate the water supply valve behind the unit to verify position is turned on.

CAUTION: We recommended that the water supply valve, behind unit, be

turned off during non-business hours.

W

ilbur

C

urtis

C

ompany

, i

nC

.

Models Included

• TCC2S

• TCC3S

NOTE: Water source

pressure must be a

minimum of 30 PSI

pressure at all times

to insure the quality of

the of the product.

5. Clean out the tea concentrate system before using the TCCS server. Use a Bag-in-

Box style cleaning solution to simplify the cleaning procedure. A cleaner like Bev-

Clean beverage line cleaner comes in a 3 gallon bag-in-box that connects directly to

your bag-in-box system for line cleaning (http://bevclean.com).

a. Remove the quick disconnect from the tea concentrate bag.

b. Place the BIB cleaner container next to the TCCS tea dispenser. Pull the spout

from the cleaner box through the marked area. Remove the travel cap from

spout. Don’t worry about cleaner spilling when the cap is removed. The cap has

an internal seal.

OFF

ON

ISO 9001:2008 REGISTERED

WILBUR CURTIS CO., INC.

6913 West Acco Street

Montebello, CA 90640-5403

For the latest information go

to www.wilburcurtis.com

Tel: 800-421-6150

Fax: 323-837-2410

This manual is related to the following products: