Program Menus GEMIF Brewer

P-Maintenance

Brew By Time

Brew By Volume

Displ. Brew Time

Pre-infusion

Pulse Brew

P-Maintenance (Factory set to OFF)

Press ¤ to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 9500 gallons. This

feature advances in 100 gallon increments. Press ¤ to exit.

Beeper On/Off (Factory set to ON)

Press ¤ to display ON or OFF. Pressing either < or > toggles between on and off. ¤ to set. When ON, this feature allows

you to hear a short beep each time a button is pressed.

Drip-out Mode (Factory set to 2 minutes)

Press ¤ to Select. Press < or > to move to desired time. Settings are OFF, 1, 2, 3, 4 and 5 minutes. Press ¤ to Select

time.

Warmers Default (Factory setting - MED)

Press ¤ to Select. Press < or > to adjust from OFF, HIGH (185ºF), MED (182ºF) or LOW (178ºF). These temperatures

are ±3ºF.

Displ. Brew Time (Factory set to ON)

Press ¤ to display ON or OFF. Pressing either < or > toggles between on and off. After Display Brew Time an EXIT screen

will return you to Non-Brew Prog.

Display Messages (Factory set to On)

Display Messages allows the operator to change the screen display to read “Rinse Server Before Brewing” or to turn it off.

Press ¤ to display ON or OFF. Pressing either < or > toggles between on and off. ¤ to set.

Display Timers (Factory set to OFF)

Press ¤ to display ON or OFF. Pressing either < or > toggles between on and off. This feature allows the operator to turn

off or on the display for the Quality Timer count-down. At the same time, it also turns off or on the audible alarm. Press ¤ to

set and exit.

Drip-out Mode

Beeper On/Off

Warmers Default

BREW BUTTON PROGRAMMING

Brew by Volume (Factory settings: LARGE 200oz ±8oz. MEDIUM 132oz±4oz. SMALL 64oz±4oz.)

Press ¤ to Select. Display will ask you to select a brew button, Large, Medium or Small. Press the desired brew button to

begin... when desired volume is reached press the same brew button to stop the flow. Now the volume has been set.

Brew by Time (Factory settings: LARGE 5min-25sec. MEDIUM 3min-32sec. SMALL 1min-52sec.)

Next item in the sequence is Brew by Time. Press ¤ to Select to change the brew time. Display will now show the current

time. By pressing < or > you can toggle back and forth from minutes to seconds to exit (ex). Change the time or set and exit

by pressing the ¤ button.

Pre-Infusion (Factory Disabled)

Press ¤ to Select. Current setting in seconds is displayed < to decrease or select > to increase (range from OFF to 10

through 60 seconds), ¤ to set.

If Pre-infusion is selected (ON), Cold Brew Lock is set within 5ºF of set point and Cold Brew Lock disappears from the list of

program selections. When Pre-infusion is ON, Pulse Brew disappears from the list of program selections.

Pulse Brew (Factory setting C)

Press ¤ to select, < or > to select OFF or one of five pulse patterns (A to E) . The five Pulse Brew options help “tune” or

change the coffee flavor.

Guidelines for Pulse Brew:

Filter Pack type coffees typically extract better with the A and B pulse setting.

Decaf coffees typically extract better with the B pulse setting.

High-Yield coffees typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to

suit your taste profile.

Settings D and E are manual pulse counts.

To exit from the Pulse Brew mode, select 0 for the time.

If Pulse Brew is on, Cold Brew Lock is set within 5ºF of set point and Cold Brew Lock disappears from the list of program

selections. When Pulse Brew is on, Pre-infusion disappears from the list of program selections.

Display Messages