Wilbur Curtis D1000GT User Manual
Service manual – d1000gt airpot brewer

1
Symbols
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
CAUTION: DO NOT
connect this brewer to hot
water. The inlet valve is
not rated for hot water.
CAUTION: Please use
this setup procedure
before attempting to use
this brewer. Failure to follow the
instructions can result in injury or the
voiding of the warranty.
Model
• D1000GT
3. Connect the unit to electrical outlet with appropriate amperage rating (see serial tag on machine).
4.	Once	power	has	been	supplied	to	the	unit,	flip	the	toggle	switch	to	the	‘ON’	position	(located	on	the	rear	of	
the unit), the water tank will begin to fill. When the water level in the tank reaches the probe, the heating
element(s) will turn on.
5. Water in the heating tank will require approximately a half hour before reaching operating temperature (factory
setting of 200°F). Where applicable, turn on the Universal Control Module (UCM). When the unit reaches
operating temperature, it will display “READY TO BREW”.
W
ilbur
C
urtis
C
ompany
, i
nC
.
Service Manual – D1000GT Airpot Brewer
Important Safeguards & Symbols
This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance
should be performed by an authorized Wilbur Curtis service technician.
	 •	Do	NOT	immerse	the	unit	in	water	or	any	other	liquid
	 •	To	reduce	the	risk	of	fire	or	electric	shock,	do	NOT	open	service	panels.	No	user	serviceable	parts	inside.
	 •	Keep	hands	and	other	items	away	from	hot	surfaces	of	unit	during	operation.
	 •	Never	clean	with	scouring	powders,	bleach	or	harsh	chemicals.
The Curtis G3 airpot brewer is Factory Pre-Set and Ready to Go… Right from the Box.
Following are the Factory Settings for Curtis airpot brewers:
	 •	Brew	Temperature	=	200°F
	 •	Brew	Volume	=	Set	to	vessel	requirements	(75	oz).
System Requirements:
	 •	Water	Source			20	–	90	PSI	(minimum	flow	rate	of	1	GPM)
	 •	Electrical:	See	attached	schematic	for	standard	model	or	visit	www.wilburcurtis.com	for	your	model.	
Setup Steps
1. The unit should be level (left to right - front to back), on a secure surface. 
2.	 Connect	the	water	line	to	the	water	inlet	fitting	on	the	rear	of	the	unit.	Water	volume	flow	to	the	machine	
should be consistent. Use tubing sized sufficiently to provide a minimum flow rate of 1 GPM.
NOTE: A water filtration system must be used to help maintain trouble-free operation. Air must be purged
from the cartridge prior to connection to equipment. In areas with extremely hard water, we highly
recommend the use of a Curtis approved water filter. For our full line of filters, please log on to www.wilbur-
curtis.com.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so that the unit
can be moved for cleaning.
2. This unit must be installed with adequate backflow protection to comply with applicable federal, state and
local codes.
3. Water pipe connections and fixtures directly connected to a portable water supply shall be sized, installed
and maintained in accordance with federal, state, and local codes.
For the latest specifications and information go to www.wilburcurtis.com