Maintenance, Lubricating vibrator, Maintenance important – Metalfab Martin Motomagnetic Electric Vibrator User Manual
Page 23: Caution, Ma int en a nce
Martin Engineering M3286-8/01
19
MOTOMAGNETIC
®
Electric Vibrators
Maintenance
IMPORTANT
Read entire section before beginning work. Allow vibrator to
cool to ambient temperature before working on it.
NOTE
All vibrators are lubricated at the factory.
CAUTION
!
Use only prescribed grease in vibrator. If a different grease is
used, vibrator can be damaged and warranty will be void.
Use only prescribed amount of grease to lubricate vibrator.
Too much grease will cause bearings to overheat and result in
premature bearing failure.
Lubricating
vibrator
1. See Table V for lubrication schedule and amount of grease required for
your vibrator. Unless specified otherwise, lubricate the vibrator after each
2000 hours of operation.
CAUTION
!
For 3600 rpm machines operating continuously or for long
periods of time, reduce lubrication time and amount as shown
in step 2. Failure to do so could run bearings dry and destroy
unit.
2. If motor housing temperatures exceed 194° F (90° C), cut lubrication time
and amount in half for every 18° F (10° C) increment that meets or
exceeds 194° F (90° C). For example, if CD9-1410 motor housing
temperature is 204° F (96° C), use 4.5 grams of grease per bearing every
1000 hours. (Maximum bearing temperature allowed is 248° F [120° C].)
For motor housing temperatures above 212° F (100° C), consult Martin
Engineering or a representative.
NOTE
Kluber grease may be purchased from Martin Engineering by
calling 800-544-2947 or from Kluber Lubrication by calling
603-434-7704.
3. For CD9, CD12, and CD18 model vibrators, lubricate frame size 35
and larger vibrators with Kluber Isoflex NBU 8EP grease only. For CD36
model vibrators, lubricate with Kluber Isoflex NBU15 grease only.
Lubricate as follows:
a. Clean vibrator case around grease fitting with clean shop towel.
b. Insert grease gun into grease fitting. Add grease.
Ma
int
en
a
nce