Figure 4. installing restraining cable, Warning, Installation – Metalfab Martin Motomagnetic Electric Vibrator User Manual
Page 11
![background image](/manuals/646385/11/background.png)
Martin Engineering M3286-8/01
7
MOTOMAGNETIC
®
Electric Vibrators
WARNING
!
If vibrator is mounted more than 6 in. (152 mm) above
ground, install cable securing vibrator to structure. Without
cable, vibrator could fall and cause injury.
8. Secure vibrator to structure by installing MARTIN
®
BBAC Cable Kit,
P/N 32271, or equivalent as follows (cable is included with Mount Kit for
Electric Vibrators, P/N 32401-XX):
a. Weld D-ring (A, Figure 4) onto structure wall (B) above vibrator.
Figure 4. Installing Restraining Cable
b. Loop 1/4-in. (6 mm) wire cable (C) through vibrator lifting eye (D)
and D-ring on structure wall.
c. If using a MARTIN
®
W-Beam Mount, also loop cable through D-ring
on W-Beam (E) as shown. Take up slack so cable is taut.
d. Apply thread-sealing compound to nuts on cable clamps (F). Install six
cable clamps (two on each end and two on loop around D-ring on
W-beam) to secure cable to vibrator eye and D-rings. Torque nuts on
cable clamps according to drawing B-32401-XX supplied with Mount
Kit for Electric Vibrators.
e. Trim loose ends of wire cable.
A
B
D
C
E
F
A.
B.
C.
D.
E.
F.
D-ring
Structure wall
Wire cable
Vibrator lifting eye
D-ring on W-Beam
Cable clamp (6)
B
Installation