Installation, Manifold pressure gas conversion, Gas connection – B&C Technologies IP Series Commercial Ironer User Manual
Page 16

Manifold Pressure
Gas Conversion
Be sure to check the manifold pressure. Use
a manometer to verify that the manifold
pressure matches the information on the
serial sticker and the type of gas being used.
A separate gas regulator (locally obtained)
must be installed if the incoming line
pressure is greater than 12 inches water
column pressure.
1. Connect the manometer to the
pressure connection on the gas valve
(disconnect gas service).
2. Restore gas service, and determine
the pressure while the burner is ignited.
The pressure must match the indicated
manifold pressure on the serial sticker.
Notice: Do not connect a machine
configured for Natural Gas to LP Gas
service or vice-versa without a qualified
service technician doing a proper
conversion. The correct regulator kit must
be installed in the gas valve and all gas
nozzles internally must be changed. See
figure below.
Installation
Gas Connection
16
After the reconfiguration is complete, the
manifold pressure must be verified for
proper operation. All instructions supplied
with the regulator kit must be followed to
ensure proper operation.