Installation, General specifications – B&C Technologies IP Series Commercial Ironer User Manual
Page 13

Installation
13
Model
Metric
US
Number of Rolls
Roll Diameter
mm
inch
355.6
14
355.6
14
355.6
14
Working Width
mm
inch
2000
78
2159
85
2540
100
Speed Range
m/min
ft/min
1.8-11
6-36
1.8-11
6-36
1.8-11
6-36
Dimensions
Width
mm
inch
2500
98.5
2500
105.5
2500
120.5
Depth
mm
inch
715
28.2
715
28.2
715
28.2
Height
mm
inch
1744
68.7
1744
68.7
1744
68.7
Canopy Height
mm
inch
434
17
434
17
434
17
Exhaust System
Air Flow
cmm
cfm
30.6
1080
30.6
1080
30.6
1080
Exhaust Duct
mm
inch
203.2
8
203.2
8
203.2
8
Drive Information
Drive Motor
kW
HP
0.37
0.5
0.37
0.5
0.37
0.5
Blower Motor
kW
HP
0.37
0.5
0.37
0.5
0.37
0.5
Steam
Consumption
Pressure
bar
psi
6.3-8.8
90-125
6.3-8.8
90-125
6.3-8.8
90-125
Inlet Size
mm
inch
19.1
0.75
19.1
0.75
19.1
0.75
Outlet Size
mm
inch
12.7
0.5
12.7
0.5
12.7
0.5
Gas
Heat Input
Gas Inlet Size
mm
inch
12.7
0.5
12.7
0.5
12.7
0.5
Electric Heat
Heating Element
Weight & Shipping
Net Weight
kg
lbs
477
1051
520
1144
600
1320
Shipping Weight
kg
lbs
527
1162
570
1254
650
1430
160,000
40
1
2.3
190,000
46
IP-1485
IP-14100
1
2
BTU
150,000
kW
36
1
BHP
1.8
IP-1478
General Specifications
Specifications subject to change without notice