P o w e r R e q u i r e m e n t s

CellarPro cooling systems should be plugged into a dedicated outlet connected
to a 15-amp circuit. These cooling units can be used in 187-254V single-phase
environments at 50Hz, and use approximately 6.3 amps during its “on” cycle. The
power plug provided is Nema 6-15P 15A 250V Plug (Male). It has a screw cover
plug housing with internal lug connections, and can be swapped easily to conform
to local plug configurations.

A number of variables, including the minimum set point, the temperature in the
ambient environment, the insulation of the cellar, and the thermal mass inside
the cellar, will affect the cooling unit’s runtime. It is normal for the cooling unit
to run up to 75 percent of the time in order to maintain proper conditions inside
the cellar.

Select a power receptacle (Front or Rear) and plug the provided power cord into
that receptacle. Plug the other end of the power cord into a dedicated 15 amp
circuit. A surge-protected circuit is recommended. Set the power selector
switch to energize the appropriate receptacle used (Front or Rear).