As shown above, the drain line should drop, then rise (but stay below the
height of the fitting), and then drop again into a drain or bucket. Then, fill the
trap with water. The condensate trap will allow any excess moisture inside
the cooling unit to overcome the static pressure and flow out of the drain line.

 Ducted Installations

1. Ductwork may be attached to the discharge only, or to both the discharge and

return adapters.

2. The unit is capable of operating with 30 equivalent meters of total ductwork, or

15 equivalent meters for both the discharge and return ducting, for the rear
and the front of the cooling unit. Elbows or bends will reduce this length. Use
a duct sizing program to determine the total equivalent meters of a specific
duct routing design, or consult the manufacturer for recommendations.

3. The “High” fan speed setting is recommended for long duct runs and as

ambient temperatures rise.