Vintage Cellars 4200VSI 220V CellarPro User Manual
Page 26

26
Alarms
The cooling unit has both an audible notification and a visual alarm indicator
(shown in “red” on the control panel) that are activated when an alarm is triggered.
Please note: the temperature alarms (HA, HA2, LA and LA2) are disabled during
the first 23 hours of operation after the cooling unit is plugged in and/or turned on.
The control panel also will flash a code for each alarm, as follows:
Alarm
Code
What it means
What to do
P1, P3
Probe Failure
Call CellarPro at 877.726.8496
HA
The temperature
inside the cellar is
too warm (above
21.1°C for more than
1 hour)
Check if the cellar has a leak
Check if door was left open
Lower the ambient temperatures
HA2 The
condenser
temperature is too high
(above 60°C for 2 hours)
Check for appropriate installation, ventilation,
ambient conditions and cooling capacity
Replace/Clean clean the condenser filter
Check for obstructions to the intake and/or
exhaust vents
Check that the condenser fan is operating
LA The
temperature
insidethe cellar is too
cold (below 7.2°C)
Raise the ambient temperature
Raise the “Minimum Set Point”
LA2
The temperature at the
condenser coils
(outside the cabinet)
has dropped below the
alarm temperature
setting
Lower the alarm temperature setting:
1. Depress the “Set” and “Down” button for
three seconds until the display reads
“HY”
2. Depress the “Set” and “Down” button for
seven seconds until “PR2” flashes on the
display
3. Using the “Down” button, scroll until the
display reads “AL2”
4. Depress the “Set” button and lower the
alarm temperature setting to your desired
setting