Initial Start-Up
When power is applied to the unit, the control will
briefly display all symbols, and the Compressor
symbol will be displayed (if unit is calling for cooling).
There may be a brief delay prior to the evaporator and
condenser fans turning on. When the evaporator and
condenser fans are activated the “FAN” symbol will
turn on.
Normal Unit Cycle
After the bottle probe has reached the set point (all
units are shipped with the set point of 55°F and a dif-
ferential of 1°F), the unit will turn off. The WhisperKOOL
Humidity Management (WHM) is an adjustable feature
which allows the customer the convenience of man-
aging the humidity enhancement of their wine cellar.
The WHM is one of the many Customer Preference Se-
lection features which allow the customer the ability
to fine tune the controls. Feature is off from the factory
but can be turned on with the “FON” parameter.
Anti Short Cycle
The Anti Short Cycle ensures that the compressor will
remain off for a period of 3 minutes after the unit
has reached the set point to allow the pressure in
the refrigeration unit to equalize prior to starting the
compressor.
Anti Frost Cycle
The Anti Frost Cycle is a precautionary measure, as
icing or frosting of the coil does not occur during nor-
mal operation. The unit will go through an anti frost
cycle when the evaporator temperature reaches 26°.
During the Anti Frost cycle, the unit will stop cooling
and run the indoor fan to provide air flow across the
indoor coil, which will melt any frost accumulation.
Bottle Probe Failure Protection
In the event that a bottle probe should fail, the APST
(Advance Product Safety Technology) will automati-
cally transition the Refrigeration Compressor cycles
to a pre-determined time series (based on detailed
laboratory testing), which will ensure that the product
is kept within the safe range.
Remote Control (optional)
The control panel can be installed or mounted sepa-
rately from the cooling unit itself (remotely), using the
supplied cable. This option provides unique flexibility
for installing the Extreme Series cooling unit in your
wine cellar. The remote option must be specified when
the unit is ordered.
Note: Remote Control is generally standard with a
“Ducted Unit”.
Ducting and Ventilation Options
The ventilation system is ideal for ducting. The option-
al collars fit standard ventilation ducting allowing the
installer to vent air to and from the unit for optimum
performance (please see specifications for details).
Unit OPERATION:
Standard and Remote Controls