Live weighing program menu – Rice Lake IQ plus 390-DC Live Weighing Option Configuration and Operation Instructions User Manual
Page 2

2
IQ plus 390-DC Live Weighing Option
Serial Data Considerations
W h e n o p e r a t i n g i n l ive w e i g h i n g m o d e w i t h
AUTOPRT set OFF, ensure that the acquired weight
display time (DSPTIM parameter) is set to a large
enough value to allow the operator time to press the
key to generate a demand print ticket, if
required. In live weighing mode, the
key can
send data to the serial port only while the acquired
weight is displayed; pressing the
key at any
other time acquires a new weight sample.
Demand print data (SERIAL menu STREAM
parameter set OFF) uses the NFMT ticket format if a
tare is in the system, GFMT if no tare is acquired or
entered. The
ticket and the
ticket both represent the animal weight.
When streaming continuous data (SERIAL menu
STREAM parameter set to LFT or INDUST), the
weight data displayed or printed depends on the value
set for the WEIMOD parameter: If WEIMOD is set to
BLANK and no weight data is shown on the current
display, streamed weight data is also blank.
Live Weighing Program Menu
Figure 1. ANIMAL Submenu on IQ plus 390-DC PROGRM Menu
XXXXXXX
XXXXXXX
VERS
PROGRM
PFORMT
SERIAL
CALIBR
CONFIG
FORMAT
ANIMAL
ACCESS
ENABLE
DSABLE
000040
000001–
002400
SMPTIM
000080
000001–
999999
DSPTIM
OFF
ON
WEIMOD
NORMAL
BLANK
AUTPRT
GO
DELAY
PWRUPM
• • •
(same as standard
PROGRM menu)
sample and display times
specified in 0.1-second intervals
PROGRM Menu / ANIMAL Submenu
Parameter
Choices
Description
Level 3 Submenus
ACCESS
ENABLE
DSABLE
Animal mode access. Specify ENABLE to use the live weighing option; specify DSABLE to
operate as standard indicator.
SMPTIM
000040
number
Sample time. Specifies, in 0.1-second intervals, the sample time during which animal
weight is acquired. The default value (000040) is 4 seconds.
DSPTIM
000080
number
Display time. Specifies, in 0.1-second intervals, how long the acquired animal weight is
displayed. The default value (000080) is 8 seconds.
AUTPRT
OFF
ON
Automatic print. Specifies whether animal weight data is automatically sent to the serial
port once the weight is acquired.
WEIMOD
NORMAL
BLANK
Weigh mode. Specifies whether the indicator display shows the current scale weight
(NORMAL) or is blank (no weight data) when the acquired weight display time expires.
Table 1. ANIMAL Submenu Parameters on PROGRM Menu