Disable character – Rice Lake Datalogic PowerScan PD7100 Series Laser Scanner User Manual
Page 76

RS-232/USB-Com Interfaces
68
PowerScan
®
PD7100 Corded
Disable Character
Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
To set the value:
1. Determine the desired character or value. A setting of 0xFF indicates the the Dis-
able Character is not used (not available).
2. Use the
on the inside back cover of this manual to find the hex equiv-
alent for the desired character/value.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
4. Scan the barcode: SELECT DISABLE CHARACTER SETTING.
5. Scan the appropriate two alpha-numeric characters from the keypad in
, that represent the desired character/value in step
above. The second
character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See
for some examples of how to set this
feature.
Table 12. Disable Character Setting Examples
NOTE
Setting to previously defined characters such as XON, XOFF, or host
commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option
has been set as 7
Data Bits.
STEP
ACTION
EXAMPLES
1
Desired character/value
‘d’
‘}’
‘D’
Disable Command
Not Used
2
Hex equivalent
0x64
0x7D
0x44
0xFF
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT DISABLE CHARACTER VALUE SETTING
5
Scan Two Characters From
‘6’ and ‘4’
‘7’ and ‘D’
‘4’ and ‘4’
‘F’ AND ‘F’
6
Scan ENTER/EXIT PROGRAMMING MODE