Rice Lake Coin Counting Scales User Manual
Page 2

Ver. 3.20 Customer Specification : To enter this mode, press the following key
sequence : [R][1][4][1] ie. Numeric keys 1, 4 ,1 while holding Rezero key.
Spec No.
Bit 3
Bit 2
Bit 1
Bit 0
0
Tare When
Change Scale
0 = Old Tare
1 = New Tare
Digital Tare
Accumulation
0 = No
1 = Yes
Terminator
0 = Carriage
Return
1 = Carriage
Return Linefeed
(RS-232only)
Weighing unit
0= U.W. per/1000
1 = A.P.W.
1
0 0 0 0
Power Auto Off Function
0000 : Auto Power Off Disable when Net Wt. = 0
0001 ~ 1111 : Duration to activate Power Off (in Minutes). (1 to 15 minutes)
2
1 0 0 0
Scale Specification
00 : Gram 01 : Kg
10 : Lb 11 : not used
Kg/Lb Lamp Inhibit
0 : No
1 : Yes
Inventory Disp by Gross Key
0: Gross Disp
1: No of Invnt
3
0 1 1 1
RS-232 port commands
00 = standard RS-232
01 = ctm-290 (slip printer)
10 = tm-200( with cutter command)
11 = tm-200(with feed for tear off)
Print commands
00 = bcp-30 (barcode printer)
01 = ctm-290 (slip printer)
10 = tm-200( with cutter command)
11 = tm-200(with feed for tear off)
4
1 0 0 1
Set New Item
Code during
Normal Mode
0: Yes 1: No
Insufficient sample Level
00 : 0.1 %
01 : 0.2%
10 : 0.0%
Negative Counting
0 : No
1 : Yes
5
1 0 1 1
Sampling time
for Unit Weight
Calculation
0 : 10 times
1 : 5 times
Unit Wt. Auto
Re-computing
0 : No
1 : Yes
Date Order
00:Year, Month, Date
01: Date, Month, Year
11: Month, Date, Year
6
1 1 0 1
Display
Accuracy of Unit
Weight
0 : No
1 : Yes
Clear All Input
Key in One
Touch
0 = Yes
1 = No
RS232 Continue
Sending High
0 = High
1 = Low
Auto Shift To Next Position
After Two Key of Teraoka Code
Entry
0 = No 1 = Yes
7
0 0 0 0
Set Point Buzzer
0 : Yes 1 : No
Set Points:
0: Latch
1: No Latch
Set Point Type
00 : %Quantity 10 : Quantity
01 : %Weight 11 : Weight
8
0 0 1 0
RS-232C
(Connection
(Force Balance)
0 : No 1 : Yes
RS-232C (FB)
Data Length
(Optional)
0 :7 bits1 : 8 bits
RS-232C (FB) Baud Rate
(Optional)
00:1200 10 4800
01:2400 11 9600
9
0 1 1 1
RS-232C (FB)
Stop Bit
(Optional)
0 : 1 bit 1 : 2 bits
Force Balance
Type
0: SHG-300
1: TP-200
RS-232C (FB) Parity Bit
(Optional)
00 : No 10 : Not Used
01 : Odd 11 : Even
10
0 1 1 1
RS-232C
Connection
(PC / Printer)
0 : No 1 : Yes
RS-232C (PC/PRN)
Data Length
(Optional)
0 :7 bits 1 :8 bits
RS-232C (PC/PRN) Baud Rate
(Optional)
00 : 1200 10 : 4800
01 : 2400 11 : 9600
PRINTER:
0: Eltron or Epson
1: BCP-30
11
0 1 0 0
RS-232C
(PC/PRN)
Stop Bit
(Optional)
0 : 1 bit
1 : 2 bits
0 = output on RS-232
comma delimited file
1 = paper tape output
on printer port (in prog mode)
RS-232C (PC/PRN)Parity Bit
(Optional)
00 : No 10 : Not Used
01 : Odd 11 : Even
12
1 0 1 0
RS-232 (PC/PRN) Output
(Optional)
00 : Not Available
01 : When Counting Condition(PC)
10 : By
∗∗∗∗ Key
11 : In Both Cases (DP122)
Eltron format
0 = eltron fixed
format
1 = custom
download format
RS232C (PC/PRN)
With Header
0: Yes
1: No
13
0 0 0 1
RS232(PC/PRN)
Header:
0: Code
1: Title
RS232 CONNECTOR
Sub Din Sub Din
000 : Printer .......... Force Bal. 101 : Force Bal ........PC
001 : Force Bal. ......Printer 010 : Printer .............PC (*1)
100 : PC ..................Force Bal. 011 : PC ...............Printer(*2)
14
1 0 1 0
RS-232C
Connection
(Barcode Pen)
0 : No 1 : Yes
RS-232C (BCP)
Data Length
(Optional)
0 :7 bits1 : 8 bits
RS-232C (BCP) Baud Rate
(Optional)
00 : 1200 10 : 4800
01 : 2400 11 : 9600
15
0 0 1 1
RS-232C (BCP)
Stop Bit
(Optional)
0 : 1 bit 1 : 2 bits
RS232C (BCP)
With Header
0: Yes
1: No
RS-232C (BCP)Parity Bit
(Optional)
00 : No 10 : Not Used
01 : Odd 11 : Even
16
normally
set
0 0 0 1
_ _ _ _
SCALE 1:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
SCALE 2:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
17
normally
set
1 0 1 1
_ _ _ _
SCALE 3:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
SCALE 4:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
ALL SCALES ARE UNIQUE AND EACH MUST HAVE THEIR OWN CHANNEL LOCATION.
18
0 0 0 0
Set Point TTL Output
0: Active Low
1: Active High
Number Of Set Point:
000: 2 Set Points
001: 3 Set Points
010: 4 Set Points
011: 5 Set Points
100: 6 Set Points
19
0 0 0 0
Display “Not F” Message For
Items Not Stored In Memory
0 : Yes 1 : No
Link To IMS
0 = NO
1 = YES
Type of Force
Balance (Japan
Version Only)
0: SHG-300
1: HR-60
Print When
Pressing + or –
key in Add Mode
0: yes
1: No
Weight and Measures Specification : To enter this mode, enter the numeric keys 1,4,2 while
pressing the Rezero Key. The Span Switch must be “ON” to enter this mode.
Spec No.
Bit 3
Bit 2
Bit 1
Bit 0
20
_ _ _ _
Minimum Display ( Scale 1)
00 : 2 10 : 5
01 : 1 11 : 10
Minimum Display (Scale 2)
00 : 2 10 : 5
01 : 1 11 : 10
21
_ _ _ _
Weight Decimal Point Position (Scale 1)
000 : 00000 011 : 00.000
001 : 0000.0 100 : 0.0000
010 : 000.00
22
_ _ _ _
Weight Decimal Point Position (Scale 2)
000 : 00000 011 : 00.000
001 : 0000.0 100 : 0.0000
010 : 000.00
23
0 0 1 1
Display Resolution
00 : 1/10,000 10 : 1/2,500
01 : 1/5,000 11 : Not Used
Zero Setting Range
00 : Unlimited 10 : +- 10% FS
- 10% F.S.
01 : +- 2% FS 11 : Unlimited
24
0 0 0 0
Masked Display at
Minus Wt.
0 : Gross
1 : Net
Display at Minus Wt.
0 :Minus
Display
1 :Masked
Zero Lamp
Lighting Method
0 : Gross
1 : Net
When No AC, Display Mask When
Battery Low or No Battery.
0 : Yes 1 : No
25
0 0 _ 0
Scale Starting
Method
0 : Automatic
1 : Manual
IR Mode protected by
Span Switch
0 : No
1 : Yes
Scale Type
0 : Single Scale
1 : Double Scale
Gross Mode Available
0 : Yes
1 : No
26
0 0 1 1
Zero Tracking
When Tare
0 : Yes 1 : No
Weight Reset when
Tare
0 : Yes 1 : No
Initial Start Range
00 : Unlimited 10 : +- 10% FS
- 10% FS
01 : +- 2% FS 11 : Unlimited
27
0 1 0 0
Comma Display
0 : No
1 : Yes
Digital Tare Setting
0 : No 1 : Yes
Tare Range
00 : 100%FS 10 : 5% FS
01 : 50%FS 11 : Unlimited
28
0 0 0 0
Auto Tare clear
when Rezero
0 : No
1 : Yes
Automatic Unit Weight Clear Condition
00 : Over Net 5d and Gross 21d
and Weight Stable
01 : >= Net 1d and Weight Stable
10 : >= Net 1d and Quantity >0
and Weight Stable
Automatic Unit Weight Clear
0 : No
1 : Yes