Rice Lake Coin Counting Scales User Manual
Dmc-290 data sheet, Spec settings

Spec
No.
Bit 3
Bit 2
Bit 1
Bit 0
29
0 0 0 0
Digital Tare Rounding
0 : Tare Exactly
1 : Round to Nearest
Increment
Tare Value Exchange
0 : Yes
1 : No
Tare Addition
0 : Yes
1 : No
Tare Subtraction
0 : Yes
1 : No
30
Load Cell Sensitivities Selection (mV/V) (Scale 1)
SPC MIN MAX
SPC MIN MAX
SPC MIN MAX
SPC MIN MAX
auto
adjust-
ing
1 0 0 1
0000
0001
0010
0011
3.46
3.00
2.59
2.25
4.00
3.46
3.00
2.59.
0100
0101
0110
0111
1.95
1.69
1.46
1.27
2.25
1.95
1.69
1.46
1000
1001
1010
1011
1.09
0.95
0.82
0.71
1.27
1.09
0.95
0.82
1100
1101
1110
1111
0.61
0.53
0.46
0.40
0.71
0.91
0.53
0.46
31
Load Cell Sensitivities Selection (mV/V) (Scale 2)
SPC MIN MAX
SPC MIN MAX
SPC MIN MAX
SPC MIN MAX
auto
adjust-
ing
1 0 0 1
0000
0001
0010
0011
3.46
3.00
2.59
2.25
4.00
3.46
3.00
2.59.
0100
0101
0110
0111
1.95
1.69
1.46
1.27
2.25
1.95
1.69
1.46
1000
1001
1010
1011
1.09
0.95
0.82
0.71
1.27
1.09
0.95
0.82
1100
1101
1110
1111
0.61
0.53
0.46
0.40
0.71
0.91
0.53
0.46
32
1 0 1 0
Calibration Mode
protected by Span
Switch
0 : Yes 1 : No
Battery Low Lamp
BATTERY 1
0: Yes
1: No
Auto Exit from Add
Mode
0 : No
1 : Yes
External Load Cell
(Scale 3)
0: No
1: Yes
33
0 _ _ _
Over Weight Mask at
0 : +1d
1 : +9d
Weight Decimal Point Position (Scale 3)
000 : 00000 011 : 00.000
001 : 0000.0 100 : 0.0000
010 : 000.00
34
0 0 0 0
NOT USED
(For Scale 1)
0 :For Std / Normal Load
Cell
1: For abnormal load cell
with too large offset.
A/D Board (Scale 1)
00 : Normal
01 : Prevent from Small vibration/ fast change in
display
10 : Prevent from Medium vibration
11 : Prevent from Large
slow change in display
35
0 0 0 0
NOT USED
(For Scale 2)
0 :For Std / Normal Load
Cell
1: For abnormal load cell
with too large offset.
A/D Board (For Scale 2)
00 : Normal
01 : Prevent from Small vibration/ fast change in
display
10 : Prevent from Medium vibration
11 : Prevent from Large
slow change in display
36
_ _ 0 0
Minimum Display ( Scale 3)
00 : 2 10 : 5
01 : 1 11 : 10
A/D Board (For Scale 3)
00 : Normal
01 : Prevent from Small vibration/ fast change in
display
10 : Prevent from Medium vibration
11 : Prevent from Large
slow change in display
37
Load Cell Sensitivities Selection (mV/V) (Scale 3)
SPC MIN MAX
SPC MIN MAX
SPC MIN MAX
SPC MIN MAX
auto
adjust-
ing
1 0 0 1
0000
0001
0010
0011
3.46
3.00
2.59
2.25
4.00
3.46
3.00
2.59.
0100
0101
0110
0111
1.95
1.69
1.46
1.27
2.25
1.95
1.69
1.46
1000
1001
1010
1011
1.09
0.95
0.82
0.71
1.27
1.09
0.95
0.82
1100
1101
1110
1111
0.61
0.53
0.46
0.40
0.71
0.91
0.53
0.46
38
0 0 1 0
(For Scale 3)
0 :For Std / Normal
Load Cell
1: For abnormal load
cell with too large
offset
Digital Tare When Loaded
0: Allow
1:Not Allow
Internal Count
0 : 500,000
1: 1,000,000
Stability Check When
Changing Scales
0 : Yes
1 : No
39
0010
NOT USED
NOT USED
REZERO WHEN
CHANGING SCALE
(V2.15+)
0: No
1: Yes
DMC-290 DATA SHEET
DEALER DEMO - Y / N
Serial Number
END USER:
Sales Order No.
OPTIONS
Customer
SCANNER S/N:
Technician
PRINTER S/N:
Date
CUSTOM FORMAT
FUNCTIONAL TEST
FUNCTIONAL TEST
1
KEYBOARD
ENTRY
16
SET
POINT
ITEM
1 2 3 4 5 6
2
DIGITAL
TARE
17
SET
POINT
GEN.
1 2 3 4 5 6
3 TARE
18
OVERRANGE
BLANKING
4
AUTO TARE CLEAR
[ON]
[OFF]
19
AUTO POWER OFF
MIN.
5
LB / KG SWITCH
20
DATE SETTING
6 NEGATIVE
COUNT
21
APPEARANCE
7 RECOMPUTE
22
BAR
CODE
READER
SCANNER
PEN
8
MEMORY STORAGE
23
SPEC SWITCH SETTING
[ON]
[OFF]
9
AUTO UNIT WT CLEAR
[ON]
[OFF]
24
MEMORY CLEANED
10
INSUFFICIENT SAMPLE
25
MAIN BOARD S/N T.H.A.
#
11
ACCUMULATE
26
A/D NO. #
LOT NO #
12 BATTERY
(MEMORY
BACKUP) [ON]
[OFF]
SPEC SETTINGS
13
BATTERY POWER SWITCH
[ON]
[OFF]
REZERO 1-4-1
13
26
14 SOFTWARE
VERSION
00 14 27
15 RS-232
PORT
01 15 28
02 16 29
03 17 30
04 18 31
05 19 32
PLATFORM / SCALE 1
APPLIED
DISPLAY
06 REZERO
1-4-2
33
S/N
0
07 20 34
Model
1/4
08 21 35
Capacity
1/2
09 22 36
Grads
3/4
10 23 37
Zero count
Full
11 24 38
12
25
39
- - - -
PLATFORM / SCALE 2
APPLIED
DISPLAY
Q.C. LIST -
✓
✓
✓
✓
S/N
0
INSTRUCTION MANUAL
QUICK GUIDE
Model
1/4
SPIDER
1.
2.
3.
4.
Capacity
1/2
PLATTER
1.
2.
3.
4.
Grads
3/4
POWER CORD
UNLOCKING TOOL
Zero count
Full
PACKED BY
CHECKED BY
PLATFORM / SCALE 3
APPLIED
DISPLAY
PLATFORM / SCALE 4
APPLIED
DISPLAY
S/N
0
S/N
0
Model
1/4
Model
1/4
Capacity
1/2
Capacity
1/2
Grads
3/4
Grads
3/4
Zero count
Full
Zero count
Full