12
Chair Scale Technical and Operating Instructions
Option 5 allows for live
or dynamic weighing
OP5 = 0
Hold the Kg-Lb key for browsing
through the options. Double click on
the Kg-Lb key to change the options
value or
to advance to the next step, press the
REWEIGH key.
0=Disable
1=Enable
Option 6 allows you to
either enable or
disable the hold
function on the scale
OP6 = 1
Hold the Kg-Lb key for browsing
through the options. Double click on
the Kg-Lb key to change the options
value or
to advance to the next step, press the
REWEIGH key.
0=Disable
1=Enable
Option 7 allows you to
either enable or
disable the baby scale
function.
OP7=0
Hold the Kg-Lb key for browsing
through the options. Double click on
the Kg-Lb key to change the options
value or
to advance to the next step, press the
REWEIGH key.
0=Disable
1=Enable
Note: Leave set to 0
Option 8 allows you to
choose between 9
volts and 6 volts
OP8 = 1
Hold the Kg-Lb key for browsing
through the options. Double click on
the Kg-Lb key to change the options
value or
to advance to the next step, press the
REWEIGH key.
0=9 volts
1=6 volts
Note: Leave set to 1
Option 9 allows you to
select the
communications
protocol.
OP9 = 1
Hold the Kg-Lb key for browsing
through the options. Double click on
the Kg-Lb key to change the options
value or
to advance to the next step, press the
REWEIGH key.
0= escape
1= standard protocol
Option 10 allows you
to enable the user
menu.
OP10 = 1
Hold the Kg-Lb key for browsing
through the options. Double click on
the Kg-Lb key to change the options
value or
to advance to the next step, press the
REWEIGH key.
0= enable
1= disable
Step
Function
Display
Available Parameters
Table 4-1. Configuration Mode Menu