Removed the EXIT key during Setup mode.
•
Added a progress message during the clear of
memory and loading a user program (see
Version 3.09
•
The battery replacement procedure has been
updated (see Section 2.9 on page 15).
•
A TOKENS parameter has been added to the
SERIAL menu to allow changing the data
stream tokens from the indicator front panel
(see Section 3.2.2 on page 34).
•
Values for SWAP parameter on the FLDBUS
menu have been changed to allow greater
flexibility in byte-swapping for fieldbus cards
(see Section 3.2.8 on page 50).
•
Improved database handling. Database access
by multiple simultaneous requests is now
controlled by allowing one read or write
o p e r a t i o n a t a t i m e , o n a f i r s t - c o m e ,
first-served basis.
Version 3.08
•
A new value, KBDPRG, on the Port 2 serial
menu allows keyboard scans to be passed
directly to an
i R i t e
user program (see
•
Support for negative tracking has been added
to the ALGOUT menu (see Section 3.2.7 on
•
A new stream token, Z, has been added to the
stream format status identifiers to
indicate center-of-zero (see Table 10-8 on
Version 3.07
•
Support has been added for the dual-channel
analog output card (PN 103138) and the
ControlNet interface card (PN 103136).
•
New OVRBASE parameter, on the
REGULAT submenu of the FEATURE menu,
allows specification of calibrated or scale zero
as the base for overload calculation. See
page 44 for more information.
•
A new top-level menu, FLDBUS, is now
shown if a DeviceNet, Profibus, EtherNet/IP,
or ControlNet is installed.The two parameters
u n d e r t h e FL D B U S m e n u a l l o w b y t e
swapping to be enabled (SWAP parameter)
and for the transfer size of the swapped bytes
t o b e s p e c i f i e d ( D ATA S I Z E ) . S e e
S e c t i o n 3 . 2 . 8 o n p a g e 5 0 f o r m o r e
information.
•
The default A/D sample rate (SMPRAT
parameter on the SCALES menu) has been
changed from 120 to 30 Hz.
•
The KEXIT command has been removed and
r e p l a c e d w i t h K S AV E E X I T. ( S e e
Section Table 9-1. on page 86.)
•
Error codes returned on the XE serial
command have been updated (see Table 10-3
Version 3.05-3.06
•
Support for local/remote indicator configurations
provides function equivalent to a legal-for-trade
remote display with keypad for truck scale and
similar applications. See Section 10.5 on
page 108 for more information.
•
The description for setting rate of change (ROC)
parameters has been changed. See Table 3-3 on
page 28 for details.
•
New values have been added to the STREAM
parameter on the SERIAL menu to allow
streaming of keypad events to another indicator
(4KEYS, KEYPAD) and, for the local/remote
function, to send the complete display image
(DISPLAY). See Section 3.2.2 for more
information.
•
Reprinting of any previous print transaction is
now supported by the alibi feature. The feature is
enabled using the ALIBI parameter on the
FEATURE menu; print transactions can be
recalled by assigning an
Alibi
softkey, also
configured using the FEATURE menu (see
•
New IMAGE parameter on the FEATURE menu
allows inversion of the display image
(blue-on-white or white-on-blue) for support of
the outdoor display option. See Section 3.2.3.
•
Display and printing of audit trail information is