5

Decimal Rotation Configuration

See Table 2-5 below for information on configuring dip switch for decimal rotation. See Section 3.2 on page 11 for
more information on decimal rotation.

Table 2-5. Decimal Rotation Configuration

SW1-1

SW1-2

Parallel Output Format

0

0

No rotation

0

1

Rotate left enable

1

0

Rotate right enable (primary only)

1

1

Reserved

Polarity Bit Select

See Table 2-6 below, for information on configuring polarity bit select mode.

See Section 3.3 on page 11 for more

information on polarity switch.

Table 2-6. Polarity Bit Select Configuration

SW1-3

State

1

+ Polarity (logic 1 = +5V) ; – Polarity (logic 0 = common)

0

+ Polarity (logic 0 = common); – Polarity (logic 1 = +5V)