Config Menu

Cellpro Multi4

Firmware VX.XX

Start

Apply power to charger

Press & Hold

Mode button

Press & Hold to set Amps

Press & Hold to

set Auto Start

CHOOSE SPLY AMPS

LIMIT @ X.XXA

USE AUTO START

>Yes

EXIT

Hold for More

USE AUTO START

>Yes

USE AUTO START

>No

CHOOSE SPLY AMPS

LIMIT @ X.XXA

Release

Release

Press to change Amps

Press

Press

Release

to Preset Menu (see page 4)

Other User Preset operations

n

To remove a User Preset: See “Clearing a User Preset.” Thereafter, that slot will show EMP-

TY PRESET

until you load a Library Preset into it.

n

To load a Library Preset into any slot: See “Loading a Library Preset.” If the slot was empty,

this will create a new User Preset; if the slot already had a User Preset, this will overwrite it.

n

To back up / restore presets using the Charge Control Software: See “Working with files.”

Strategies for organizing User Presets

Suppose all your packs can be handled with a small group of User Presets, and you don’t need

any of the other User Presets (at least not now). What’s the most efficient way to organize your

core presets?

n

If you aren’t using the Charge Control Software: Follow the instructions in “Loading a Li-

brary Preset” to put your core presets in adjacent slots. Use the instructions in “Clearing a

User Preset” to remove the User Presets you don’t need. Now, when you move through the

Preset Menu on the charger, use the “reverse press” technique when you see EMPTY PRESET

in the display—that will let you quickly move forward and back through your core presets.

n

If you are using the Charge Control Software: In the Presets tab, drag the presets you want

to the top of the list. For the presets you don’t need, set their visibility to Hide. Finally, click

Update Charger. Now, only your core User Presets will appear in the Presets Menu. (De-

tails are in “Using the Charge Control Software.”)

Configuring input current limiting and Auto Start

Press and hold the Mode button while applying power to the charger to access the Config Menu.

n

CHOOSE SPLY AMPS limits how much current the char-

ger draws from the power supply.

n

USE AUTO START: Yes enables you to start charg-

ing using the selected preset simply by connecting the

pack. No requires you to start charging using the START

CHARGE

screen in the Operations Menu.

(These can also be set via the Charge Control Software.)