beautypg.com

Fma limited warranty, Quick start for the cellpro multi4 charger – ProgressiveRC Multi4 FMA Cellpro User Manual

Page 20

background image

20

090917

FMA limited warranty

FMA, Inc. warrants this product to be free of manufacturing defects for the term of one year from the date of pur-

chase. Should any defects covered by this warranty occur, the product shall be repaired or replaced with a unit of

equal performance by FMA or an authorized FMA service station.
Limits and exclusions
This warranty may be enforced only by the original purchaser, who uses this product in its original condition as

purchased, in strict accordance with the product’s instructions. Units returned for warranty service to an FMA

service center will be accepted for service when shipped postpaid, with a copy of the original sales receipt or war-

ranty registration form, to the service station designated by FMA.
This warranty does not apply to:

n

Consequential or incidental losses resulting from the use of this product.

n

Damage resulting from accident, misuse, abuse, neglect, electrical surges, reversed polarity on connectors,

lightning or other acts of God.

n

Damage from failure to follow instructions supplied with the product.

n

Damage occurring during shipment of the product either to the customer or from the customer for service

(claims must be presented to the carrier).

n

Damage resulting from repair, adjustment, or any alteration of the product by anyone other than an authorized

FMA technician.

n

Installation or removal charges, or damage caused by improper installation or removal.

Call (301) 668-4280 for more information about service and warranty repairs.

Quick start for the Cellpro Multi4 Charger

Assumes Auto Start is OFF. Refer to manual for complete operating details.

A. Connect charger to a 12V to 16V (maximum), 5A power source.
B. Welcome screen (Cellpro Multi4) times out, then charger displays Preset Menu.
C. In Preset Menu, press Mode button to display User Preset for pack you want to charge.
D. Connect pack to charger.
E. Press and hold Mode button. When you see START CHARGE, release Mode button. Display

briefly shows CHECKING PACK.

F. Next screen displays preset’s chemistry and prompts you to verify it is same as pack’s chemis-

try. This is a safety check.

n

If displayed chemistry matches pack chemistry, press Mode button to start charging. Go

to step G.

or

n

If displayed chemistry does not match pack chemistry, do nothing. Screen will time out

and Preset Menu will be displayed. Go to step C.

G. During charging:

n

Press Mode button to view charging data screens.

n

To stop charging:

a. Press and hold Mode button to see STOP CHARGE? >No.

b. Press Mode button to see STOP CHARGE? >Yes. Press and hold Mode button.

c. When you see CHARGER STOPPED, press Mode button to see Preset Menu (step C).

H. When charging is complete, charger beeps three times repeatedly and displays ELAPSED

[time] / [chemistry] DONE

. Press Mode button to review charging data screens.

I. Disconnect pack from charger. Display shows PACK REMOVED.
J. Press Mode button to return to Preset Menu.