beautypg.com

9 ppc_seeprom, 8 plx pci express switch, 1 plx_lanegood – Kontron AT8402 Diagnostics Manual User Manual

Page 29: Ppc_seeprom - 21, Plx pci express switch - 21, Plx_lanegood - 21, At8402 diagnostics running on the carrier

background image

AT8402

Diagnostics running on the Carrier

Page 2 - 21

AT8402 CLI Reference Manual

The basic modes must be combined to build a test scenario which tests the flash

memory completely. The test goal is not to test the flash device itself but the correct

connection to the CPU’s data and address lines. Data line connection is done by the

testpattern used in the ppc-flash utility, which includes all combinations of adjacent

data lines. The following testpattern is used:

{ 0xCCAAAACC,0xAAAACCAA,0xAACCAAAA,0x00000000,

0xFFFFFFFF,0x00000000,0xCCAAAACC,0xAAAACCAA }

Parameters: see above

Returns:

0 - command executed successfully

-1 - an error occured during execution

Failure impact

PPC-00060008 diagnostic code results from an flash read/write error. The impact
is loss of applications running on carrier host processor. This impacts at least
Ethernet functionality and command line interface.

2.7.9

PPC_SEEPROM

Test group:

Diagnostics

Test case:

ppc

Test procedure: PPC_SEEPROM
Test host:

Carrier

Test IC:

quickturn

Test mode:

normal

Diagnostic code: PPC-00060009

SEEPROM test.

Description

Read and the SEEPROM used for storing low-level board configuration e.g. SPD data

for RAM and check data for consitency.

Failure impact

PPC-00060009 diagnostic code results from an SEEPROM read error. The impact
is loss of applications running on carrier host processor. This impacts at least
Ethernet functionality and command line interface.

2.8

PLX PCI Express Switch

2.8.1

PLX_LANEGOOD

Test for lane good status of PCI Express switch.
Test group:

Diagnostics

Test case:

ppc

Test purpose:

PLX_LANEGOOD

Test host:

Carrier

Test IC:

quickturn