11.3
OEM Event/Reading Types
OEM (Kontron) specific sensor types and codes are presented in the following table.
Table 12: OEM Event/Reading Types
OEM
SENSOR
TYPE (CODE)
OEM
EVENT/READING
TYPE (CODE)
DESCRIPTION
Firmware Info 1 (C0h)
70h
Internal Diagnostic Data
Firmware Info 2 (C0h)
71h
Internal Diagnostic Data
Initialization Agent (C2h)
03h
('digital' Discrete)
Offsets / events:
0: Initialization O.K.
1: Initialization Error
FRU Agent (C5h)
0Ah
(Discrete)
FRU initialization agent, using a standard reading type.
Post Value (C6h)
6Fh
(sensor type specific)
Error is detected if the POST code is != 0 and doesn't
change for a defined amount of time.
In case of no error:
Bits [7:0] = POST code (payload Port 80h)
In case of error:
Bits [15:0] = 4000h
Data2 = POST code, low nibble
Data3 = POST code, high nibble
Firmware Upgrade Manager
(C7h)
6Fh
(sensor type specific)
Offsets / events:
0 : First Boot after upgrade
1 : First Boot after rollback (error)
2 : First Boot after errors (watchdog)
3 : First Boot after manual rollback
4..7 : Reserved
8 : Firmware Watchdog Bite, reset occurred
Board Reset (CFh)
03h
('digital' Discrete)
Data 2 contains the reset type:
…WARM = 0
…COLD = 1
…FORCED_COLD = 2
…SOFT_RESET = 3
…MAX = 4
Data 3 contains the reset source:
…IPMI_WATCHDOG = 0
…IPMI_COMMAND = 1
…PROC_INT_CHECKSTOP = 2
…PROC_INT_RST = 3
…RESET_BUTTON = 4
…POWER_UP = 5
…LEG_INITIAL_WATCHDOG = 6
…LEG_PROG_WATCHDOG = 7
…SOFTWARE_INITIATED = 8
…SETUP_RESET = 9
…UNKNOWN = 0xFF