3 set control state (firmware hub, boot order), Set control state, Cp6002 ipmi firmware user guide – Kontron CP6002 IPMI User Manual
Page 29
CP6002
IPMI Firmware User Guide
ID: 1039-1613, Rev. 2.0
Page 29
10.3
Set Control State (Firmware Hub, Boot Order)
Please note that parameters which are set while the board is write protected are only valid until
the next IPMI firmware reset.
Table 7:
Set Control State
COMMAND
LUN
NetFn
CMD
Set Control State (Firmware Hub/EFI Flash, Boot Order)
00h
OEM = 3Eh
20h
REQUEST DATA
Byte
Data Field
1
Control ID:
00h: EFI Flash selection
9Dh: EFI Boot Order Configuration
2
Control State for EFI Flash selection:
(These settings are stored in EEPROM and applied (to logic) each time the IPMI controller
detects power-on)
00h = EFI Flash selection is not inverted
01h = EFI Flash selection is logically inverted
Please note that this selection will be automatically toggled by the IPMI controller during a
failing boot process. Other payload sided settings may additionally modify this selection.
Control State for BIOS Boot Order Configuration:
(These settings are stored in EEPROM and applied (to logic) each time the IPMI controller
detects power-on)
00h .. 07h = Selected EFI Boot Order Configuration.
00h selects the default Boot Order which is selected in the EFI menu.
EFI Boot Order Configuration:
00h = Boot order is according to EFI setup (default)
01h = Next boot device is: Floppy
02h = Next boot device is: HDD
03h = Next boot device is: CD
04h = Next boot device is: Network
05h = Next boot device is: USB Floppy
06h = Next boot device is: USB HDD
07h = Next boot device is: USB CDROM
RESPONSE DATA
Byte
Data Field
1
Completion Code