Ipmi firmware user guide cp6002 – Kontron CP6002 IPMI User Manual
Page 32
IPMI Firmware User Guide
CP6002
Page 32
ID: 1039-1613, Rev. 2.0
Bh /
NNN:IPMB 5V
Voltage (02h) /
Threshold ( 01h)
2204h / 2204h /
1212h
IPMB 5V supply
N
Ch /
NNN:Fan1 Speed
Fan (04h) /
Threshold (01h)
0000h / 0000h /
1B1Bh
Speed [rpm] Fan 1
N
Dh /
NNN:Fan2 Speed
Fan (04h) /
Threshold (01h)
0000h / 0000h /
1B1Bh
Speed [rpm] Fan 2
N
Eh /
NNN:Last Reset
OEM (CFh) /
‘digital’ Discrete (03h)
0002h / 0000h /
0003h
Board reset event
N
Fh /
NNN:Slot System
Entity presence (25h) /
Sensor-specific (6Fh)
0000h / 0000h /
0003h
Board is in System Slot
(SYSEN)
N
10h /
NNN:PCI Present
Entity presence (25h) /
Sensor-specific (6Fh)
0000h / 0000h /
0003h
Board is selected (BDSEL)
and in system slot (SYSEN)
N
11h /
NNN:CTCA chassis
Entity presence (25h) /
Sensor-specific (6Fh)
0000h / 0000h /
0003h
Value is always 1
N
12h /
NNN:Board PwrOff
Power supply (08h) /
‘digital’ Discrete (03h)
0000h / 0000h /
0003h
N
13h /
NNN:IPMI WD
Watchdog2 (23h) /
Sensor-specific (6Fh)
010Fh / 0000h /
010Fh
IPMI Watchdog
Y
/ 010Fh
14h /
NNN:IPMB State
IPMB status change (F1h) /
Sensor-specific (6Fh)
000Fh / 0000h /
000Fh
IPMB-0 state (refer to
PICMG 3.0 Rev 2.0, 3.8.4.1)
N
15h /
NNN:ACPI State
System ACPI Power State
(022h) / Sensor-specific (6Fh)
7FFFh / 0000h /
7FFFh
System ACPI Power State
N
16h /
NNN:Health Error
Platform Alert (24h) /
‘digital’ Discrete (03h)
0000h / 0000h /
0003h
Aggregates states (power,
temperatures etc.).
Visualization by the Health
LED.
N
17h /
NNN:CPU 0 Status
Processor (07h) /
Sensor-specific (6Fh)
0463h / 0400h /
04E3h
CPU status.
Offset 0ah: “Processor
Automatically Throttled”
Y
/ 0402h
18h /
NNN:POST Value
POST value OEM (C6h) /
Sensor-specific (6Fh)
4000h / 0000h /
40FFh
POST code value (port 80h)
N
19h /
NNN:FWH0 BootErr
Boot error (1Eh) /
Sensor-specific (6Fh)
0008h / 0008h /
0008h
Firmware Hub 0 (Boot Flash
0) boot error
Y
/ 0008h
1Ah /
NNN:FWH1 BootErr
Boot error (1Eh) /
Sensor-specific (6Fh)
0008h / 0008h /
0008h
Firmware Hub 1 (Boot Flash
1) boot error
Y
/ 0008h
1Bh /
NNN:XMC present
Entity Presence (25h) /
Sensor-specific (6Fh)
0000h / 0000h /
0003h
Presence of XMC-A board
N
1Ch /
NNN:XMC-2 pres
Entity Presence (25h) /
Sensor-specific (6Fh)
0000h / 0000h /
0003h
Presence of XMC-B board
N
1Dh /
NNN:Pwr Denied
Platform Alert (24h) /
‘digital’ Discrete (03h)
0002h / 0002h /
0003h
1 = o.k., no alert, power not
denied
N
1Eh /
NNN:FRU Agent
OEM FRU Agent (C5h) /
Discrete (0Ah)
0140h / 0000h /
0147h
FRU Initialization Agent
state
Y
/ 0140h
Table 9:
Sensor List
SENSOR Number
/
ID string
SENSOR TYPE (CODE) /
EVENT/READING TYPE
(CODE)
Ass. Mask /
Deass. Mask /
Reading Mask
DESCRIPTION
LED I1on
error /
Reading
Mask