2 sensor thresholds, Thresholds - standard and e2 temperature range, Voltage sensor thresholds – Kontron CP6002 IPMI User Manual
Page 34: Ipmi firmware user guide cp6002

IPMI Firmware User Guide
CP6002
Page 34
ID: 1039-1613, Rev. 2.0
11.2
Sensor Thresholds
The CP6002 CPU module is available for two different operating temperature ranges. For each
operating temperature range, standard and extended (E2), a set of temperature thresholds for
the sensors is defined. The thresholds defined in Table 10 are the same for both temperature
ranges except for sensor 04h. The far right column indicates the thresholds for the E2 range
for the sensor 04h.
Table 11 provides voltage sensor thresholds.
Table 10: Thresholds - Standard and E2 Temperature Range
Sensor Number /
ID string
01h /
NNN:Temp
CPU
02h /
NNN:Temp
PCH
03h /
NNN:Temp
Graphic
04h /
NNN:Temp
Board
(E2 RANGE)
04h /
NNN:Temp
Board
Upper non-recoverable
115 °C
116 °C
110 °C
95 °C
95 °C
Upper critical
105 °C
111 °C
100 °C
90 °C
90 °C
Upper non critical
95 °C
101 °C
90 °C
85 °C
85 °C
Normal max
90 °C
96 °C
85 °C
75 °C
75 °C
Nominal
80 °C
86 °C
75 °C
65 °C
65 °C
Normal min
3 °C
3 °C
3 °C
0 °C
- 40 °C
Lower non-critical
1 °C
n.a.
1 °C
- 1 °C
- 41 °C
Lower critical
n.a.
n.a.
n.a.
- 3 °C
- 43 °C
Lower non-recoverable
n.a.
n.a.
n.a.
- 5 °C
- 45 °C
Table 11: Voltage Sensor Thresholds
Sensor Number /
ID string
07h /
NNN:Board
3.3V
08h /
NNN:Board
5VIPMI
09h /
NNN:Board
5.0V
0Ah /
NNN:Board
12V
0Bh /
NNN:IPMB
5V
Upper non-recoverable
n.a.
n.a.
n.a.
n.a.
n.a.
Upper critical
3.503 V
5.004 V
5.310 V
12.715 V
5.310 V
Upper non critical
n.a.
n.a.
n.a.
n.a.
n.a.
Normal max
3.460 V
4.938 V
5.245 V
12.598 V
5.245 V
Nominal
3.302 V
4.697 V
5.007 V
12.012 V
5.007 V
Normal min
3.202 V
4.455 V
4.769 V
11.426 V
4.769 V
Lower non-critical
n.a.
n.a.
n.a.
n.a.
n.a.
Lower critical
3.173 V
4.389 V
4.704 V
11.309 V
4.704 V
Lower non-recoverable
n.a.
n.a.
n.a.
n.a.
n.a.