Hi-6022 field probe, Hi-6022 specifications – ETS-Lindgren HI-6153 Electric Field Probe User Manual
Page 46
46 |
Battery-Operated Field Probes: HI-6022 Field Probe
HI-6022 Field Probe
The
ETS-Lindgren HI-6022 Field Probe
provides broadband frequency coverage
and wide dynamic range that satisfies the
demands of most test requirements.
The frequency response of the HI-6022 is
10 kHz to 1 GHz, and the dynamic range is
2 to 800 Volts per meter (V/m).
HI-6022
S
PECIFICATIONS
Dynamic Range:
2.0–800 Volts per meter (V/m)
Ranges:
Single
Typical Frequency Response:
10 kHz–1 GHz
10 kHz–30 kHz: +0.5 dB, -2.5 dB
30 kHz–1 GHz: ±1 dB
Typical Frequency Response
with Correction:
10 kHz–1 GHz: ±0.9 dB
Linearity:
±0.5 dB @ 27 MHz
Isotropicity:
±0.5 dB @ 400 MHz
Overload Withstand:
> 1,500 V/m CW
Fiber Optic Cable Connector:
Standard FSMA
Probe Mount:
1/4–20 UNC tapped hole (internal thread)